OSHA SearchOSHA records by employer

Integrity Underground, Inc.: OSHA inspections and violations

Brighton, Colorado · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$6,300current penalties
Jul 24, 2015last inspection

OSHA has inspected Integrity Underground, Inc. once in Colorado.

The inspection began on Jul 24, 2015 after a complaint, in Brighton.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $10,500 and now stand at $6,300, 40% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Integrity Underground, Inc. averages $6,300 (1 cited inspection).

Integrity Underground, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Integrity Underground, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340806298 OPENED JUL 24, 2015Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Jan 29, 2020

W Bromley Ln & Fulton Ave, Brighton, CO 80601 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,800$1,680Oct 30, 2015Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$2,800$1,680Oct 30, 2015Final
Citation 1, item 3a
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,900$2,940Oct 30, 2015Final
Citation 1, item 3b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Oct 30, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Colorado

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.