Interior Building Systems Corporation: OSHA inspections and violations

Manassas, Virginia · Other Millwork (including Flooring) · NAICS 321918

3inspections
12citation items
$7,965current penalties
Nov 1, 2017last inspection

OSHA has inspected Interior Building Systems Corporation 3 times in Virginia since 2003.

The latest one began on Nov 1, 2017 as a planned inspection, in Manassas.

Those inspections ended with 12 citation items: 10 serious and 2 other-than-serious.

Penalties were first proposed at $8,455 and now stand at $7,965, 6% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 5 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Interior Building Systems Corporation averages $7,230 (1 cited inspection).

Interior Building Systems Corporation: OSHA citation items per year, 2003 to 2017
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

246employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Interior Building Systems Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342744216 OPENED NOV 1, 2017Closed

Planned · Complete · Safety · 45 employees at the site · Closed Jun 1, 2018

8501 Buckeye Timber Drive, Manassas, VA 20109 · Wood Office Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,850$1,850Feb 2, 2018Final
Citation 1, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,690$2,690Feb 2, 2018Final
Citation 1, item 3a
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$2,690$2,690Feb 2, 2018Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Feb 2, 2018Final
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Feb 2, 2018Final

Inspection 312646656 OPENED OCT 2, 2008Closed

Planned · Complete · Safety · 30 employees at the site · Closed Dec 2, 2008

8501 Buckeye Timber Drive, Manassas, VA 20109 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$700$420Oct 22, 2008Closed
Citation 1, item 1b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Oct 22, 2008Closed
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$525$315Oct 22, 2008Closed
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 22, 2008Closed
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Oct 22, 2008Closed
Citation 1, item 2d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Oct 22, 2008Closed

Inspection 306817826 OPENED OCT 22, 2003Closed

Planned · Complete · Safety · 14 employees at the site · Closed Oct 23, 2003

9205-c Vassau Court, Manassas Park, VA 20111 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 23, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.303 · Electrical equipment, general requirements

Other other millwork (including flooring) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.