OSHA SearchOSHA records by employer

Interiors by BI, LLC: OSHA inspections and violations

Marietta, Georgia · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

2inspections
16citation items
$21,962current penalties
Jan 24, 2020last inspection

Since 2020, OSHA inspectors have visited Interiors by BI, LLC in Georgia 2 times.

The most recent inspection opened on Jan 24, 2020 on a referral, in Marietta.

In all, OSHA issued 16 citation items: 8 serious and 8 other-than-serious.

The proposed penalties came to $25,446; today they stand at $21,962, 14% less.

The rule cited most here is 1910.134 (respiratory protection), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Interiors by BI, LLC averages $10,981 across 2 cited inspections.

Interiors by BI, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

147employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Interiors by BI, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344719349 OPENED JAN 24, 2020Closed

Referral · Partial · Health · 7 employees at the site · Closed Apr 29, 2022

4012 Kingston Court Suite C, Marietta, GA 30067 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$2,892$1,150May 1, 2020Final
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,892$1,150May 1, 2020Final
Citation 1, item 2b
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$0$0May 1, 2020Final
Citation 2, item 1 Other-than-serious$0$0May 1, 2020Final
Citation 2, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0May 1, 2020Final
Citation 2, item 2b
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0May 1, 2020Final
Citation 2, item 2c
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0May 1, 2020Final

Inspection 344567292 OPENED JAN 16, 2020Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Jun 17, 2022

4012 Kingston Court Suite C, Marietta, GA 30067 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$4,048$4,048Jul 9, 2020Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$4,048$4,048Jul 9, 2020Final
Citation 1, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,048$4,048Jul 9, 2020Final
Citation 1, item 4
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$4,048$4,048Jul 9, 2020Final
Citation 1, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,470$3,470Jul 9, 2020Final
Citation 2, item 1
29 CFR 1910.106(e)(9)(iii) · Flammable liquids
Other-than-serious$0$0Jul 9, 2020Final
Citation 2, item 2
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jul 9, 2020Final
Citation 2, item 3
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jul 9, 2020Final
Citation 2, item 4
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 9, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.106(e)(9)(iii)

(iii) Waste and residue. Combustible waste material and residues in a building or unit operating area shall be kept to a minimum, stored in covered metal receptacles and disposed of daily.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(g)(7)

(7) “No Smoking” signs. “No smoking” signs in large letters on contrasting color background shall be conspicuously posted at all spraying areas and paint storage rooms.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.95 · Noise

Other wood kitchen cabinet and countertop manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.