OSHA SearchOSHA records by employer

J&R Construction: OSHA inspections and violations

Austin, Texas · Roofing Contractors · NAICS 238160

6inspections
15citation items
$12,920current penalties
Nov 18, 2020last inspection

OSHA has inspected J&R Construction 6 times in Texas since 1991.

The latest one began on Nov 18, 2020, in Fort Stockton.

Those inspections ended with 15 citation items: 13 serious and 2 other-than-serious.

Penalties were first proposed at $16,013 and now stand at $12,920, 19% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and J&R Construction averages $4,735 (2 cited inspections).

J&R Construction: OSHA citation items per year, 1991 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch J&R Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345030936 OPENED NOV 18, 2020Closed

Unprogrammed other · Partial · Safety · 8 employees at the site · Closed Aug 1, 2025

2005 Sunset Ave, Fort Stockton, TX 79735 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,470$3,470Jan 6, 2021Final

Inspection 344405782 OPENED OCT 23, 2019Closed

Planned · Partial · Safety · 8 employees at the site · Closed Dec 30, 2022

2117 Brandy Wine, Pecos, TX 79772 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,410$2,500Oct 29, 2019Final
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$3,410$2,500Oct 29, 2019Final
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,273$1,000Oct 29, 2019Final

Inspection 307246736 OPENED APR 6, 2006Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Aug 27, 2007

14107 Rodman, El Paso, TX 79922 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.25(a) · Housekeeping
Serious$450$450Apr 13, 2006Closed
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$750$750Apr 13, 2006Closed
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$750$750Apr 13, 2006Closed
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Apr 13, 2006Closed

Inspection 306069030 OPENED APR 21, 2004Closed

Unprogrammed other · Complete · Safety · 45 employees at the site · Closed Jul 6, 2004

Sante Fe Ridge, San Antonio, TX 78207 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$600$600Jun 8, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 8, 2004Closed

Inspection 107427171 OPENED OCT 28, 1992Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 5, 1995

6000 Shepherd Mountain Cove, Austin, TX 78730 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$450Dec 10, 1992Closed
Citation 1, item 2a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$450$450Dec 10, 1992Closed
Citation 1, item 2b
29 CFR 1926.451(a)(13) · Scaffolds, general requirements
Serious$0$0Dec 10, 1992Closed
Citation 2, item 1
29 CFR 1926.300(a) · Tools—Hand and Power: general requirements
Other-than-serious$0$0Dec 18, 1992Closed

Inspection 108761743 OPENED JUN 6, 1991Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 5, 1991

84 Robert Martinez Jr. St., Austin, TX 78702 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Jul 19, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.