OSHA SearchOSHA records by employer

J. Miller Utilities Inc.: OSHA inspections and violations

Austin, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

4inspections
7citation items
$4,455current penalties
Jan 29, 2015last inspection

Since 1998, OSHA inspectors have visited J. Miller Utilities Inc. in Texas 4 times.

The most recent inspection opened on Jan 29, 2015 as a planned inspection, in Leander.

In all, OSHA issued 7 citation items: 6 serious and 1 other-than-serious.

The proposed penalties came to $11,675; today they stand at $4,455, 62% less.

The rule cited most here is 1926.800 (underground construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. J. Miller Utilities Inc. averages $2,100 across 1 cited inspection.

J. Miller Utilities Inc.: OSHA citation items per year, 1998 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch J. Miller Utilities Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340219021 OPENED JAN 29, 2015Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 19, 2015

Nwc Of Osage Drive And N. Lakeline Blvd., Leander, TX 78646 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,500$2,100Feb 5, 2015Final

Inspection 304384340 OPENED MAY 5, 2001Closed

Referral · Partial · Safety · 4 employees at the site · Closed May 22, 2001

6010 W. Parmer Lane, Austin, TX 78758 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.800(b)(1) · Underground construction
Serious$2,000$2,000May 11, 2001Closed
Citation 1, item 2
29 CFR 1926.800(d) · Underground construction
Serious$2,000$0May 11, 2001Closed
Citation 1, item 3
29 CFR 1926.800(g)(3) · Underground construction
Serious$1,000$0May 11, 2001Closed

Inspection 303419790 OPENED MAR 13, 2001Closed

Referral · Partial · Safety · 60 employees at the site · Closed Aug 1, 2001

6010 W. Parmer Lane, Austin, TX 78758 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,000$250Jul 12, 2001Closed

Inspection 302338025 OPENED OCT 23, 1998Closed

Referral · Complete · Safety · 20 employees at the site · Closed Jan 7, 1999

6010 W. Parmer Lane, Austin, TX 78758 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(e)(2)(i) · Trench protection
Serious$175$105Dec 16, 1998Closed
Citation 2, item 1
29 CFR 1926.602(a)(9)(ii) · Earthmovers and forklifts in construction
Other-than-serious$0$0Dec 16, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.602(a)(9)(ii)

(ii) No employer shall permit earthmoving or compacting equipment which has an obstructed view to the rear to be used in reverse gear unless the equipment has in operation a reverse signal alarm distinguishable from the surrounding noise level or an employee signals that it is safe to do so.

29 CFR 1926.652 · Trench protection

29 CFR 1926.652(a)(1)

(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:

29 CFR 1926.652(e)(2)(i)

(2) Additional requirements for support systems for trench excavations. (i) Excavation of material to a level no greater than 2 feet (.61 m) below the bottom of the members of a support system shall be permitted, but only if the system is designed to resist the forces calculated for the full depth of the trench, and there are no indications while the trench is open of a possible loss of soil from behind or below the bottom of the support system.

29 CFR 1926.800 · Underground construction

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.