Jack's Window Cleaning, LLC: OSHA inspections and violations

Centennial, Colorado · Other Services to Buildings and Dwellings · NAICS 561790

1inspections
5citation items
$13,000current penalties
Nov 24, 2025last inspection

OSHA inspectors have visited Jack's Window Cleaning, LLC in Colorado one time.

It opened on Nov 24, 2025 after a complaint, in Centennial.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The proposed penalties came to $20,258; today they stand at $13,000, 36% less.

The rule cited most here is 1910.333 (working near live electrical parts), 2 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,200 penalty. Jack's Window Cleaning, LLC averages $13,000 across 1 cited inspection.

Jack's Window Cleaning, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

134employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Jack's Window Cleaning, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348612870 OPENED NOV 24, 2025Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Aug 25, 2026

S Liverpool St & E Euclid Dr Saddle Rock Ranches Entrance, Centennial, CO 80016 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2 Serious$4,965$4,500May 6, 2026Final
Citation 1, item 3
29 CFR 1910.333(c)(3)(i)(a)(1) · Working near live electrical parts
Serious$4,965$4,500May 6, 2026Final
Citation 1, item 4
29 CFR 1910.333(c)(7) · Working near live electrical parts
Serious$4,965$2,000May 6, 2026Final
Citation 1, item 5
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$4,965$2,000May 6, 2026Final
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$398$0May 6, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(2)

(2) Additional requirements for unqualified persons. Employees who are covered by paragraph (a) of this section but who are not qualified persons shall also be trained in and familiar with any electrically related safety practices not specifically addressed by §§ 1910.331 through 1910.335 but which are necessary for their safety.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(c)(3)(i)(a)(1)

(i) Unqualified persons. (A) When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances:

29 CFR 1910.335 · Safeguards for personnel protection

Other other services to buildings and dwellings employers in Colorado