OSHA SearchOSHA records by employer

JBL Craftsman Construction LLC: OSHA inspections and violations

Menomonee Falls, Wisconsin · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
9citation items
$19,867current penalties
Apr 24, 2025last inspection

JBL Craftsman Construction LLC has 4 OSHA inspections on record in Wisconsin, the first in 2020.

OSHA's last visit started on Apr 24, 2025 as a planned inspection, in Pewaukee.

Across those inspections OSHA issued 9 citation items: 6 serious, 2 repeat and 1 other-than-serious.

OSHA proposed $47,451 in penalties. After settlements and reviews the total is $19,867, down 58%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. JBL Craftsman Construction LLC averages $4,967 over 4 cited inspections in that time.

JBL Craftsman Construction LLC: OSHA citation items per year, 2020 to 2025
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch JBL Craftsman Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348206988 OPENED APR 24, 2025Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 15, 2025

N15w29589 Brookstone Circle, Pewaukee, WI 53072 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,783$0May 8, 2025Final
Citation 1, item 1b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$18,914$6,219May 8, 2025Final

Inspection 347145732 OPENED DEC 6, 2023Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 16, 2024

2014 Grassland Avenue, Grafton, WI 53024 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$5,071$2,500Feb 1, 2024Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Feb 1, 2024Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$10,141$5,000Feb 1, 2024Final
Citation 3, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 1, 2024Final

Inspection 344903083 OPENED AUG 27, 2020Closed

Planned · Partial · Safety · 15 employees at the site · Closed Oct 29, 2020

1365 Ponovoma Ct, Hartland, WI 53029 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,626$3,200Sep 17, 2020Final

Inspection 344620760 OPENED FEB 11, 2020Closed

Planned · Partial · Safety · 10 employees at the site · Closed Mar 27, 2020

W136n6255 Hummingbird Way, Menomonee Falls, WI 53051 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,458$1,474Feb 28, 2020Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,458$1,474Feb 28, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other new single-family housing construction (except for-sale builders) employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.