Jeff Branham Construction: OSHA inspections and violations

Columbia, South Carolina · Poured Concrete Foundation and Structure Contractors · NAICS 238110

3inspections
8citation items
$1,000current penalties
Dec 9, 2015last inspection

OSHA has inspected Jeff Branham Construction 3 times in South Carolina since 1999.

The latest one began on Dec 9, 2015 as a planned inspection, in Columbia.

Those inspections ended with 8 citation items: 8 serious.

Penalties were first proposed at $1,000 and still stand at $1,000.

Trench protection comes up most often in these citations: 2 items under 1926.652.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jeff Branham Construction averages $325 (1 cited inspection).

Jeff Branham Construction: OSHA citation items per year, 1999 to 2015
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Jeff Branham Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341111664 OPENED DEC 9, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 11, 2016

7011 Garners Ferry Rd, Columbia, SC 29209 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$225$225Jan 7, 2016Final
Citation 1, item 2a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$100$100Jan 7, 2016Final
Citation 1, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Jan 7, 2016Final

Inspection 313487316 OPENED SEP 9, 2009Closed

Planned · Partial · Safety · 6 employees at the site · Closed Oct 30, 2009

2715 Colonial Drive, Columbia, SC 29078 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(k)(1) · Excavations
Serious$375$375Oct 20, 2009Closed
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$100$100Oct 20, 2009Closed
Citation 1, item 2b
29 CFR 1926.652(b)(2) · Trench protection
Serious$0$0Oct 20, 2009Closed
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$100$100Oct 20, 2009Closed
Citation 1, item 4
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$100$100Oct 20, 2009Closed

Inspection 302445549 OPENED AUG 23, 1999Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Sep 3, 1999

1037 Elenwood Streen, Columbia, SC 29203 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other poured concrete foundation and structure contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.