OSHA SearchOSHA records by employer

Jenkins Sign Company Inc: OSHA inspections and violations

Youngstown, Ohio · Sign Manufacturing · NAICS 339950

2inspections
35citation items
$9,201current penalties
May 3, 2017last inspection

Since 1989, OSHA inspectors have visited Jenkins Sign Company Inc in Ohio 2 times.

The most recent inspection opened on May 3, 2017 after a complaint, in Youngstown.

In all, OSHA issued 35 citation items: 26 serious and 9 other-than-serious.

The proposed penalties came to $18,255; today they stand at $9,201, 50% less.

The rule cited most here is 1910.1200 (hazard communication), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Jenkins Sign Company Inc averages $6,881 across 1 cited inspection.

Jenkins Sign Company Inc: OSHA citation items per year, 1989 to 2017
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

258employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Jenkins Sign Company Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342295888 OPENED MAY 3, 2017Closed

Complaint · Partial · Safety · 14 employees at the site · Closed Dec 26, 2018

1400 Mahoning Ave, Youngstown, OH 44509 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(2) · Spray painting and finishing
Serious$2,897$1,448Jun 19, 2017Final
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jun 19, 2017Final
Citation 1, item 2
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$2,173$1,086Jun 19, 2017Final
Citation 1, item 3
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Serious$2,173$1,086Jun 19, 2017Final
Citation 1, item 4
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,173$1,086Jun 19, 2017Final
Citation 1, item 5a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,173$1,086Jun 19, 2017Final
Citation 1, item 5b
29 CFR 1910.305(c)(4) · Electrical wiring methods
Serious$2,173$0Jun 19, 2017Final
Citation 1, item 7a
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$2,173$1,086Jun 19, 2017Final
Citation 1, item 7b
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Jun 19, 2017Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Other-than-serious$0$0Jun 19, 2017Final
Citation 2, item 2
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jun 19, 2017Final
Citation 2, item 3
29 CFR 1910.179(j)(2) · Overhead and gantry cranes
Other-than-serious$0$0Jun 19, 2017Final

Inspection 105931109 OPENED AUG 8, 1989Closed

Complaint · Complete · Safety · 11 employees at the site · Closed Nov 13, 1989

1400 Mahoning Avenue, Youngstown, OH 44509 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$120$120Aug 14, 1989Closed
Citation 1, item 2a
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$240$240Aug 14, 1989Closed
Citation 1, item 2b
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0Aug 14, 1989Closed
Citation 1, item 2c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Aug 14, 1989Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Serious$160$160Aug 14, 1989Closed
Citation 1, item 4 Serious$120$120Aug 14, 1989Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$160$160Aug 14, 1989Closed
Citation 1, item 6a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$120$120Aug 14, 1989Closed
Citation 1, item 6b
29 CFR 1910.213(h)(4) · Woodworking machinery
Serious$0$0Aug 14, 1989Closed
Citation 1, item 7
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Serious$200$200Aug 14, 1989Closed
Citation 1, item 8
29 CFR 1910.217(b)(8)(iii) · Mechanical power presses
Serious$160$160Aug 14, 1989Closed
Citation 1, item 9
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$200$200Aug 14, 1989Closed
Citation 1, item 10
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$160$160Aug 14, 1989Closed
Citation 1, item 11
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Serious$160$160Aug 14, 1989Closed
Citation 1, item 12
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$160$160Aug 14, 1989Closed
Citation 1, item 13
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$160$160Aug 14, 1989Closed
Citation 1, item 14
29 CFR 1910.1200(h) · Hazard communication
Serious$200$200Aug 14, 1989Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Aug 14, 1989Closed
Citation 2, item 2 Other-than-serious$0$0Aug 14, 1989Closed
Citation 2, item 3
29 CFR 1910.213(i)(1) · Woodworking machinery
Other-than-serious$0$0Aug 14, 1989Closed
Citation 2, item 4
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Aug 14, 1989Closed
Citation 2, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Aug 14, 1989Closed
Citation 2, item 6
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Aug 14, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(2)

(2) Interiors. The interior surfaces of spray booths shall be smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other sign manufacturing employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.