Inspection 344951942 OPENED OCT 1, 2020Closed
2605 Auction Barn Street, Cameron, TX 76520 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Sep 14, 2020: Employee makes contact with power line, receives electric sh
At 1:45 p.m. on September 14, 2020, Employee #1 was operating an aerial lift to install a junction box on the front of a building. While attempting to move closer to the building, the employee was unable to reposition the lift due to its full extension. The employee then swung the boom around, making contact with a power line. The employee sustained an electric shock and was hospitalized for treatment.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(4) · Construction safety programs |
Serious | $2,313 | $925 | Dec 14, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $2,892 | $1,157 | Dec 14, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.453(b)(2)(v) · Aerial lifts |
Serious | $2,892 | $1,157 | Dec 14, 2020 | Final |
| Citation 2, item 1 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $1,000 | $400 | Dec 14, 2020 | Final |