OSHA SearchOSHA records by employer

JJ Carpentry Corp.: OSHA inspections and violations

Rochester, New Hampshire · Framing Contractors · NAICS 238130

4inspections
11citation items
$6,400current penalties
Nov 5, 2026last inspection

Since 2023, OSHA inspectors have visited JJ Carpentry Corp. in New Hampshire 4 times.

The most recent inspection opened on Nov 5, 2026 after a complaint, in Concord and is still open.

In all, OSHA issued 11 citation items: 11 serious.

The proposed penalties came to $24,111; today they stand at $6,400, 73% less.

The rule cited most here is 1926.20 (construction safety programs), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JJ Carpentry Corp. averages $3,200 across 2 cited inspections.

JJ Carpentry Corp.: OSHA citation items per year, 2023 to 2026
Citation items per year, by inspection date.

New Hampshire · latest 90 days of OSHA records

52employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Hampshire

Checking a subcontractor, a client or your own company? Watch JJ Carpentry Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349267203 OPENED NOV 5, 2026Open

Complaint · Partial · Safety · 1 employee at the site · Open

Intersection Of Sewalls Falls Road & Abbott Road, Concord, NH 03303 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 349195255 OPENED OCT 1, 2026Open

Planned · Partial · Safety · 2 employees at the site · Open

994 Somerville Street, Manchester, NH 03103 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 346560071 OPENED MAR 10, 2023Closed

Unprogrammed related · Partial · Safety · 3 employees at the site · Closed Aug 23, 2023

Bible Hill Rd., Bennington, NH 03442 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$3,349$1,600May 12, 2023Final
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0May 12, 2023Final
Citation 1, item 1c
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,679$0May 12, 2023Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$1,600May 12, 2023Final

Inspection 346777667 OPENED FEB 21, 2023Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Oct 24, 2023

25 Tamper Dr. Unit # G5, Rochester, NH 03867 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$3,349$1,600Jun 23, 2023Final
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Jun 23, 2023Final
Citation 1, item 1c
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Jun 23, 2023Final
Citation 1, item 1d
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,349$0Jun 23, 2023Final
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,688$1,600Jun 23, 2023Final
Citation 1, item 3b
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$0$0Jun 23, 2023Final
Citation 1, item 3c
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$2,009$0Jun 23, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in New Hampshire

Alert subscribers get notified of each newly cited employer in New Hampshire the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.