OSHA SearchOSHA records by employer

Joel Medina: OSHA inspections and violations

Mission, Texas · Roofing Contractors · NAICS 238160

6inspections
8citation items
$10,218current penalties
Jul 12, 2017last inspection

OSHA has inspected Joel Medina 6 times in Texas since 2006.

The latest one began on Jul 12, 2017 as a planned inspection, in San Juan.

Those inspections ended with 8 citation items: 6 serious, 1 repeat and 1 other-than-serious.

Penalties were first proposed at $10,928 and now stand at $10,218, 6% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 5 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Joel Medina averages $2,902 (2 cited inspections).

Joel Medina: OSHA citation items per year, 2006 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Joel Medina and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342475647 OPENED JUL 12, 2017Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 7, 2022

411 Virgen De San Juan, San Juan, TX 78589 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,803$3,803Nov 24, 2017Final

Inspection 341194868 OPENED JAN 21, 2016Closed

Planned · Partial · Safety · 4 employees at the site · Closed Dec 10, 2019

126 Swordfish, South Padre Island, TX 78597 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$2,000May 25, 2016Final

Inspection 316032085 OPENED NOV 2, 2011Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 17, 2015

3401 San Diego St, Mission, TX 78572 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,000$3,000Feb 24, 2012Closed

Inspection 314953282 OPENED OCT 27, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 13, 2012

1304 Agusta Ave, Mcallen, TX 78501 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311242549 OPENED JUL 19, 2007Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 1, 2008

3300 Hwy 83, Mcallen, TX 78540 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$1,600$1,100Sep 14, 2007Closed
Citation 2, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Sep 14, 2007Closed

Inspection 309781185 OPENED MAR 1, 2006Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jun 7, 2006

200 N Conway, Mission, TX 78572 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$300$180May 11, 2006Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$225$135May 11, 2006Closed
Citation 1, item 2b
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$0$0May 11, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(22)

(22) An employee shall not carry any object or load that could cause the employee to lose balance and fall.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.