OSHA SearchOSHA records by employer

Johnson Controls Battery Group Inc: OSHA inspections and violations

Quinby, South Carolina · Storage Battery Manufacturing · NAICS 335911

4inspections
1citation items
$5,000current penalties
Oct 11, 2017last inspection

Since 2014, OSHA inspectors have visited Johnson Controls Battery Group Inc in South Carolina 4 times.

The most recent inspection opened on Oct 11, 2017 after a complaint, in Quinby.

In all, OSHA issued 1 citation item: 1 serious.

The penalties, $5,000 in total, stand where OSHA first set them.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Johnson Controls Battery Group Inc averages $5,000 across 1 cited inspection.

1 inspection on this page followed a fatal incident.

Johnson Controls Battery Group Inc: OSHA citation items per year, 2014 to 2017
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

42employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Johnson Controls Battery Group Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342731247 OPENED OCT 11, 2017Closed

Complaint · Partial · Health · 382 employees at the site · Closed Dec 19, 2017

1800 Paper Mill Road, Quinby, SC 29506 · Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341805497 OPENED SEP 28, 2016Closed

Follow-up · Partial · Safety · 369 employees at the site · Closed Oct 25, 2016

1800 Paper Mill Road, Quinby, SC 29506 · Secondary Smelting and Alloying of Aluminum · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341217693 OPENED JAN 27, 2016Closed

Fatality or catastrophe · Partial · Safety · 369 employees at the site · Closed Oct 25, 2016

1800 Paper Mill Road, Quinby, SC 29506 · Storage Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 26, 2016 (fatal): Employee struck and killed by crucible

At 9:45 a.m. on January 26, 2016, Employee #1 was placing a crucible bridge (metal trough) on top of two crucibles (bowls for molten lead) sitting on a moving Crucible Transfer System, Model H-750b, known as Crucible Train B at Furnace #1 tunnel entrance. The process was known as tapping. The crucible train was composed of four train assemblies, carrying two crucibles on each assembly. The crucible train ran on a train track measuring approximately 255 feet long from the Foundry Area into the Refinery Area. The train assembly was approximately 50 feet wide by 132 inches long by 24 feet high and weighed 4,930 Kg/10,868 lbs. A crucible is a metal bowl designed to transport smelted lead from the Foundry Area to the Refinery Area by the crucible train. The crucible outside diameter was approximately 56.5 feet by 33.5 inches high. The crucible's total width with the crucible ears on both sides was approximately 60 feet. The furnace operators were in the process of cleaning the crucibles prior to the next tap. Crucible Train B was located between Furnace #1's tunnel entrance and the wall opening leading into the Refinery Area. Employee #1 made his way to Furnace #1 tunnel entrance area. The operator started to move Crucible Train B towards Furnace #1's tunnel entrance. Two Brook Crompton pit motors, Model Number: MTR085, with approximately 7.5 horsepower, moved the crucible train back and forth from the Foundry Area to the Refinery Area at a speed of approximately .26 miles per hour. Employee #1 started to place a crucible bridge onto the moving crucible train. The crucible ear struck Employee #1's chest and pulled him in between the crucible ear and Furnace #1's right side tunnel entrance wall. The distance between the right crucible ear to the right side of tunnel entrance wall was approximately 1 inch to 2 inches. Employee #1 was killed from massive blunt chest trauma and cardiac avulsion. blunt chest trauma and cardiac avulsion.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$5,000$5,000Jul 20, 2016Final

Inspection 317494466 OPENED APR 29, 2014Closed

Referral · Partial · Health · 329 employees at the site · Closed Jul 8, 2014

1800 Paper Mill Road, Florence, SC 29506 · Storage Battery Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

Other storage battery manufacturing employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.