OSHA SearchOSHA records by employer

Jonathan Restoration, Inc.: OSHA inspections and violations

Spanish Fort, Alabama · Roofing Contractors · NAICS 238160

2inspections
7citation items
$21,052current penalties
Dec 1, 2020last inspection

Since 2020, OSHA inspectors have visited Jonathan Restoration, Inc. in Alabama 2 times.

The most recent inspection opened on Dec 1, 2020 after a fatality or catastrophe, in Spanish Fort.

In all, OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

The penalties, $21,052 in total, stand where OSHA first set them.

The rule cited most here is 1903.19 (proving cited hazards were fixed), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Jonathan Restoration, Inc. averages $10,526 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Jonathan Restoration, Inc.: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

99employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Jonathan Restoration, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345062459 OPENED DEC 1, 2020Closed

Fatality or catastrophe · Complete · Safety · 15 employees at the site · Closed May 20, 2022

10558 Eastern Shore Dr. Bldg. 1600 The Arlington @ Eastern Shore, Spanish Fort, AL 36527 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 30, 2020 (fatal): Employee is killed in fall during roof repair

At 3:00 p.m. on November 30, 2020, Employee #1, employed by a construction company, was working at a multiemployer construction project, the renovation of a multifamily residential building. The employee was tasked with replacing a section of plywood at the roof's eave. A lull material handler was being used to lift a box made on the job to the roof to deliver supplies to employees. The box was not properly secured to the lull, and when the employee stepped into the box to retrieve the plywood, the box fell off the lull's forks, causing the employee to fall. Employee #1 fell a height of 20 feet 4 inches. He sustained multiple blunt force traumatic injuries and was killed. killed.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$5,461$5,461Apr 5, 2021Final
Citation 1, item 2
29 CFR 1926.502(d)(15) · Fall protection systems
Serious$5,461$5,461Apr 5, 2021Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$438$438Aug 23, 2021Final

Inspection 345013825 OPENED NOV 5, 2020Closed

Unprogrammed other · Partial · Safety · 15 employees at the site · Closed Sep 30, 2021

10558 Eastern Shore Dr. Building 700/900, Spanish Fort, AL 36527 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,398$5,398Dec 17, 2020Final
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Dec 17, 2020Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$3,856$3,856Dec 17, 2020Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$438$438Aug 23, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.