Jose Luis Hermenegildo: OSHA inspections and violations

Conroe, Texas · Drywall and Insulation Contractors · NAICS 238310

2inspections
5citation items
$11,618current penalties
Oct 11, 2023last inspection

OSHA has inspected Jose Luis Hermenegildo 2 times in Texas since 2013.

The latest one began on Oct 11, 2023 as a planned inspection, in Wolfforth.

Those inspections ended with 5 citation items: 5 serious.

Penalties were first proposed at $11,618 and still stand at $11,618.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Jose Luis Hermenegildo averages $4,018 (1 cited inspection).

Jose Luis Hermenegildo: OSHA citation items per year, 2013 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Jose Luis Hermenegildo and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347024697 OPENED OCT 11, 2023Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 9, 2026

1413 Knight Ave, Wolfforth, TX 79382 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,009$2,009Nov 28, 2023Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,009$2,009Nov 28, 2023Final

Inspection 338929466 OPENED MAR 1, 2013Closed

Planned · Partial · Health · 2 employees at the site · Closed Jun 15, 2018

3600 Fm 1488, Conroe, TX 77384 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$2,800Mar 21, 2013Final
Citation 1, item 2
29 CFR 1926.452(w)(1) · Rules for each type of scaffold
Serious$2,800$2,800Mar 21, 2013Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,000$2,000Mar 21, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(w)(1)

(w) Mobile scaffolds. (1) Scaffolds shall be braced by cross, horizontal, or diagonal braces, or combination thereof, to prevent racking or collapse of the scaffold and to secure vertical members together laterally so as to automatically square and align the vertical members. Scaffolds shall be plumb, level, and squared. All brace connections shall be secured.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other drywall and insulation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.