Inspection 344970900 OPENED OCT 13, 2020Closed
1497 Spring Road, Stoughton, WI 53589 · Siding Contractors · OSHA's record · Phone and website on Google Maps
Incident on Oct 13, 2020 (fatal): One is electrocuted, one is injured when pole contacts power
At 9:30 a.m. on October 13, 2020, Employees #1 and #2, employed by a siding company, were erecting a pump jack scaffold at a single-family residence in preparation for installation work. The outdoor winds exceeded 17 miles per hour with even stronger gusts. As they erected a 24-foot scaffold pole support adjacent to the house, the pole made contact with a live and uninsulated 7,200-volt primary power line that ran parallel to the house. The power line was approximately 23 feet 8 inches above the ground and approximately 12 feet away from the house. Employee #1 was electrocuted. Employee #2 sustained electric shock injuries that required hospitalization and treatment. and treatment.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(1) · Construction safety programs |
Serious | $2,892 | $2,892 | Dec 18, 2020 | Final |
| Citation 1, item 2a 29 CFR 1926.21(b)(2) · Construction safety training |
Serious | $2,892 | $2,892 | Dec 18, 2020 | Final |
| Citation 1, item 2b 29 CFR 1926.451(f)(7) · Scaffolds, general requirements |
Serious | $0 | $0 | Dec 18, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.451(f)(6) · Scaffolds, general requirements |
Serious | $13,494 | $13,494 | Dec 18, 2020 | Final |