Inspection 344939764 OPENED JUL 14, 2020Closed
Pr2 Km 228.9, Ponce, PR 00717 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Ponce, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220
Since 2020, OSHA inspectors have visited JRC Consolidate Inc in Puerto Rico 2 times.
The most recent inspection opened on Jul 14, 2020 on a referral, in Ponce.
In all, OSHA issued 14 citation items: 13 serious and 1 other-than-serious.
The proposed penalties came to $38,850; today they stand at $0, 100% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JRC Consolidate Inc averages $0 across 1 cited inspection.
Puerto Rico · latest 90 days of OSHA records
109employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Puerto Rico
Checking a subcontractor, a client or your own company? Watch JRC Consolidate Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyPr2 Km 228.9, Ponce, PR 00717 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Carretera 2 Km 228.9, Ponce, PR 00717 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.302(e)(11) · Power-operated hand tools |
Serious | $3,500 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $1,750 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 3 29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring |
Serious | $3,500 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 4 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $3,500 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 5 29 CFR 1926.451(c)(2)(iii) · Scaffolds, general requirements |
Serious | $2,450 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 6 29 CFR 1926.451(c)(3) · Scaffolds, general requirements |
Serious | $2,450 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 7a 29 CFR 1926.451(f)(3) · Scaffolds, general requirements |
Serious | $2,450 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 7b 29 CFR 1926.451(f)(4) · Scaffolds, general requirements |
Serious | $0 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 8 29 CFR 1926.454(a) · Scaffold training |
Serious | $2,450 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 9 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $4,900 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 10 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $4,900 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 11 29 CFR 1926.502(b)(2) · Fall protection systems |
Serious | $3,500 | $0 | Mar 31, 2020 | Final |
| Citation 1, item 12 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $3,500 | $0 | Mar 31, 2020 | Final |
| Citation 2, item 1 29 CFR 1926.451(c)(2) · Scaffolds, general requirements |
Other-than-serious | $0 | $0 | Mar 31, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.302(e)(11)
(11) All tools shall be used with the correct shield, guard, or attachment recommended by the manufacturer.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.405(a)(2)(ii)(j)
(J) Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage.
Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.