OSHA SearchOSHA records by employer

JSC Services, LLC: OSHA inspections and violations

Spring, Texas · Site Preparation Contractors · NAICS 238910

4inspections
10citation items
$54,028current penalties
Apr 8, 2025last inspection

Since 2013, OSHA inspectors have visited JSC Services, LLC in Texas 4 times.

The most recent inspection opened on Apr 8, 2025 on a referral, in Iowa Colony and is still open.

In all, OSHA issued 10 citation items: 7 serious and 3 other-than-serious.

The proposed penalties came to $246,172; today they stand at $54,028, 78% less.

The rule cited most here is 1926.651 (excavations), 5 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JSC Services, LLC averages $17,049 across 3 cited inspections.

JSC Services, LLC: OSHA citation items per year, 2013 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites JSC Services, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 348166331 OPENED APR 8, 2025Open

Referral · Partial · Safety · 3 employees at the site · Open

2002 Meridiana Pkwy, Iowa Colony, TX 77583 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$11,585$11,585Oct 7, 2025Final
Citation 2, item 1
29 CFR 1926.652(b)(2) · Trench protection
Serious$99,308$16,550Oct 7, 2025Final
Citation 3, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$57,925$11,585Oct 7, 2025Final
Citation 3, item 2
29 CFR 1926.651(h)(1) · Excavations
Serious$57,925$0Oct 7, 2025Final

Inspection 346248701 OPENED SEP 27, 2022Closed

Planned · Partial · Safety · 8 employees at the site · Closed Jan 23, 2023

361-41 La Salle Ave 30.344118, -95.533887, Conroe, TX 77304 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$4,972$4,699Dec 2, 2022Final
Citation 1, item 3a
29 CFR 1926.652(b) · Trench protection
Other-than-serious$5,801$4,801Dec 2, 2022Final
Citation 1, item 3b
29 CFR 1926.651(h)(1) · Excavations
Other-than-serious$0$0Dec 2, 2022Final

Inspection 344931530 OPENED SEP 16, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 26, 2020

6534 Fm 1488, Magnolia, TX 77354 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(a)(9)(ii) · Earthmovers and forklifts in construction
Serious$3,856$1,928Sep 28, 2020Final

Inspection 339469041 OPENED NOV 4, 2013Closed

Planned · Complete · Safety · 16 employees at the site · Closed Jan 9, 2014

2885 Waterbend Cove, Spring, TX 77386 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(2) · Excavations
Serious$2,000$1,200Dec 12, 2013Final
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$1,680Dec 12, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.602(a)(9)(ii)

(ii) No employer shall permit earthmoving or compacting equipment which has an obstructed view to the rear to be used in reverse gear unless the equipment has in operation a reverse signal alarm distinguishable from the surrounding noise level or an employee signals that it is safe to do so.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

Other site preparation contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.