OSHA SearchOSHA records by employer

Junior Smith: OSHA inspections and violations

Saint Albans, West Virginia · Masonry Contractors · NAICS 238140

1inspections
6citation items
$4,169current penalties
Oct 28, 2016last inspection

OSHA has inspected Junior Smith once in West Virginia.

The inspection began on Oct 28, 2016 after a complaint, in Saint Albans.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $6,948 and now stand at $4,169, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Junior Smith averages $4,169 (1 cited inspection).

Junior Smith: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Junior Smith again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341873248 OPENED OCT 28, 2016Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Apr 19, 2017

201 Maccorkle Avenue, Saint Albans, WV 25177 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$2,672$1,603Nov 22, 2016Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,138$1,283Nov 22, 2016Final
Citation 1, item 3a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,138$1,283Nov 22, 2016Final
Citation 1, item 3b
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$0$0Nov 22, 2016Final
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$0$0Nov 22, 2016Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 22, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in West Virginia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.