OSHA SearchOSHA records by employer

JW Drywall, LLC: OSHA inspections and violations

Huntsville, Texas · Drywall and Insulation Contractors · NAICS 238310

2inspections
1citation items
$3,457current penalties
Jul 30, 2024last inspection

Since 2024, OSHA inspectors have visited JW Drywall, LLC in Texas 2 times.

The most recent inspection opened on Jul 30, 2024 to follow up on an earlier case, in Huntsville.

In all, OSHA issued 1 citation item: 1 serious.

The penalties, $3,457 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. JW Drywall, LLC averages $3,457 across 1 cited inspection.

JW Drywall, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

398employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch JW Drywall, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347650624 OPENED JUL 30, 2024Closed

Follow-up · Partial · Safety · 3 employees at the site · Closed Aug 16, 2024

3103 Montgomery Rd., Huntsville, TX 77340 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347423659 OPENED APR 18, 2024Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 22, 2025

3103 Montgomery Rd., Huntsville, TX 77340 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$3,457$3,457Jun 21, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(iv)

(iv) Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use.

Other drywall and insulation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.