OSHA SearchOSHA records by employer

Kadant Johnson LLC: OSHA inspections and violations

Three Rivers, Michigan · Fluid Power Valve and Hose Fitting Manufacturing · NAICS 332912

3inspections
23citation items
$4,550current penalties
Mar 9, 2021last inspection

Kadant Johnson LLC has 3 OSHA inspections on record in Michigan, the first in 2011.

OSHA's last visit started on Mar 9, 2021 as a planned inspection, in Three Rivers.

Across those inspections OSHA issued 23 citation items: 7 serious and 16 other-than-serious.

OSHA proposed $10,150 in penalties. After settlements and reviews the total is $4,550, down 55%.

Most often, OSHA cited 1910.107, spray painting and finishing (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Kadant Johnson LLC averages $1,750 over 1 cited inspection in that time.

Kadant Johnson LLC also files yearly injury logs with OSHA, summarized below.

Kadant Johnson LLC: OSHA citation items per year, 2011 to 2021
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Kadant Johnson LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345184931 OPENED MAR 9, 2021Closed

Planned · Complete · Safety · 105 employees at the site · Closed Apr 30, 2021

805 Wood Street, Three Rivers, MI 49093 · Other Services to Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12154(1)
Serious$2,000$1,000Apr 2, 2021Final
Citation 1, item 2
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$1,500$750Apr 2, 2021Final
Citation 2, item 1
29 CFR 1910.23(e)(1)(vii) · Ladders in general industry
Other-than-serious$0$0Apr 2, 2021Final
Citation 2, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Apr 2, 2021Final

Inspection 315404038 OPENED SEP 27, 2013Closed

Planned · Complete · Safety · 130 employees at the site · Closed Nov 12, 2013

805 Wood St, Three Rivers, MI 49093 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Oct 16, 2013Closed
Citation 1, item 2 Other-than-serious$0$0Oct 16, 2013Closed
Citation 1, item 3 Other-than-serious$0$0Oct 16, 2013Closed

Inspection 312000532 OPENED JUL 25, 2011Closed

Planned · Complete · Safety · 132 employees at the site · Closed Sep 20, 2011

805 Wood St, Three Rivers, MI 49093 · Fluid Power Valve and Hose Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,050$420Aug 11, 2011Closed
Citation 1, item 2 Serious$1,050$420Aug 11, 2011Closed
Citation 1, item 3 Serious$1,400$560Aug 11, 2011Closed
Citation 1, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,750$700Aug 11, 2011Closed
Citation 1, item 5
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,400$700Aug 11, 2011Closed
Citation 2, item 1 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 2 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 3 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 4 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 5 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 6
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 7 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 8 Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 9
29 CFR 1910.107(c)(2) · Spray painting and finishing
Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 10
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Aug 11, 2011Closed
Citation 2, item 11
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Aug 11, 2011Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Three Rivers site logged 2 recordable injuries or illnesses among about 150 workers: 1.2 per 100 full-time workers, against a median of 2.1 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Kadant Johnson LLC Three Rivers
Three Rivers · 2025
150 201.22.1
Kadant Johnson
Three Rivers · 2024
157 201.12.1
KJ Three Rivers
Three Rivers · 2018
125 110.82.1

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(e)(9)

(9) Grounding. Whenever flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) are transferred from one container to another, both containers shall be effectively bonded and grounded to prevent discharge sparks of static electricity.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4081.1115

29 CFR 4081.1222

29 CFR 4081.125

29 CFR 4081.1276

29 CFR 4081.2635

29 CFR 4081.3308

29 CFR 4081.3312

29 CFR 4081.4007

29 CFR 4081.5815

29 CFR 4081.632

Other fluid power valve and hose fitting manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.