Keystone Masonry Incorporated: OSHA inspections and violations

Mc Murray, Pennsylvania · Roofing Contractors · NAICS 238160

4inspections
12citation items
$3,450current penalties
Sep 18, 2015last inspection

Keystone Masonry Incorporated has 4 OSHA inspections on record in Pennsylvania, the first in 1975.

OSHA's last visit started on Sep 18, 2015 after a complaint, in Elysburg.

Across those inspections OSHA issued 12 citation items: 7 serious and 5 other-than-serious.

OSHA proposed $5,550 in penalties. After settlements and reviews the total is $3,450, down 38%.

Most often, OSHA cited 1926.59, hazard communication (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Keystone Masonry Incorporated averages $2,500 over 1 cited inspection in that time.

Keystone Masonry Incorporated: OSHA citation items per year, 1975 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

287employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Keystone Masonry Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340928746 OPENED SEP 18, 2015Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Nov 2, 2015

319 South Market Street, Elysburg, PA 17824 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$1,500Sep 30, 2015Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,000$1,000Sep 30, 2015Final

Inspection 305013104 OPENED AUG 13, 2002Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Apr 3, 2003

7350 William Ave., Fogelsville, PA 18051 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Other-than-serious$0$0Aug 20, 2002Closed

Inspection 102928439 OPENED APR 4, 1991Closed

Referral · Complete · Safety · 5 employees at the site · Closed Aug 16, 1991

Cleaver Road & Swinehart Road, Gilbertsville, PA 19525 · OSHA's record · Phone and website on Google Maps

Incident on Apr 4, 1991: Three employees injured in fall when wall collapsed

Employees #1 and #2, both masons, were on a scaffold laying the last course of c oncrete blocks on a 40 ft long by 15 ft high interior wall of a two-story townho use. Employee #3, a mason tender, was passing blocks to Employees #1 and #2. A s trong gust of wind blew the block wall onto the scaffold. As the wall and scaffo ld collapsed, the additional weight caused the first and second floors of the to wnhouse to also collapse. All three employees fell with the debris, landing in t he basement. Employees #1 and #2 sustained compound fractures and were hospitali zed. Employee #3 broke his nose.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.59(e)(1) · Hazard communication
Serious$450$300Jun 10, 1991Closed
Citation 1, item 1b
29 CFR 1926.59(g)(1) · Hazard communication
Serious$0$0Jun 10, 1991Closed
Citation 1, item 1c
29 CFR 1926.59(h) · Hazard communication
Serious$0$0Jun 10, 1991Closed
Citation 1, item 1d
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Jun 10, 1991Closed
Citation 1, item 2
29 CFR 1926.706(b) · Requirements for masonry construction
Serious$1,050$600Jun 10, 1991Closed
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jun 10, 1991Closed

Inspection 12870093 OPENED JAN 27, 1975Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 24, 1975

Mtlebanon Fed Saving Loan Bldg, Mc Murray, PA 15317 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$50$50Jan 30, 1975Closed
Citation 1, item 2
29 CFR 1926.50(d)(1) · Medical services and first aid
Other-than-serious$0$0Jan 30, 1975Closed
Citation 1, item 3
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Jan 30, 1975Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(a)(1)

(a) General requirements. (1) Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department of Transportation approved containers shall be used for the handling and use of flammable liquids in quantities of 5 gallons or less, except that this shall not apply to those flammable liquid materials which are highly viscid (extremely hard to pour), which may be used and handled in original shipping containers. For quantities of one gallon or less, the original container may be used, for storage, use and handling of flammable liquids.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

29 CFR 1926.706 · Requirements for masonry construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other roofing contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.