Inspection 348497447 OPENED SEP 10, 2025Closed
4400 S Mlk Blvd Mary & John Gray Library, Beaumont, TX 77705 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2012, OSHA inspectors have visited Kilgore Industries, LP in Texas 7 times.
The most recent inspection opened on Sep 10, 2025, in Beaumont.
In all, OSHA issued 5 citation items: 1 serious and 4 other-than-serious.
The proposed penalties came to $36,843; today they stand at $23,973, 35% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kilgore Industries, LP averages $4,158 across 3 cited inspections.
1 inspection on this page followed a fatal incident.
Kilgore Industries, LP also files yearly injury logs with OSHA, summarized below.
The Wage and Hour Division has 1 case on it since 2015, with $8,292 in back wages owed to workers.
Texas · latest 90 days of OSHA records
399employers cited
9 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Kilgore Industries, LP and get notified the morning OSHA posts a new citation for it.
Watch this company4400 S Mlk Blvd Mary & John Gray Library, Beaumont, TX 77705 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12135 Park 35 Circle, Austin, TX 78753 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $8,067 | $5,647 | May 8, 2024 | Final |
1214 East 4th Street, Austin, TX 78753 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1307 Uhland Road Bldg. 206, San Marcos, TX 78666 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3 29 CFR 1926.652(a)(1) · Trench protection |
Other-than-serious | $13,653 | $6,826 | Feb 12, 2021 | Final |
2671 Kipling St, Houston, TX 77098 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.150(c)(1)(i) · Fire protection |
Other-than-serious | $3,623 | $0 | Oct 15, 2019 | Final |
10050 Houston Oak Drive, Houston, TX 77064 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
Incident on Jul 14, 2014 (fatal): Employee is electrocuted
At approximately 1:15 p.m. on July 14, 2014, Employee #1 and his supervisor were attempting to identify wire connections that were run from lighting fixtures that were removed, to be taken out of service. Employee #1 uncoiled one of the wires that had been disconnected from the fixture and came into contact with a live part. Employee #1 was electrocuted.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.416(a)(1) · Electrical safety in construction |
Serious | $7,000 | $7,000 | Jul 31, 2014 | Final |
18300 Hwy 3, Webster, TX 77598 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $4,500 | $4,500 | Jan 23, 2013 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Houston site logged 0 recordable injuries or illnesses among about 650 workers: 0.0 per 100 full-time workers, against a median of 1.8 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Kilgore Industries, LP Houston · 2025 | 650 | 0 | 0 | 0.0 | 1.8 |
| Kilgore Dallas Houston · 2021 | 84 | 0 | 0 | 0.0 | 1.8 |
| Kilgore Conneticut Houston · 2021 | 35 | 3 | 3 | 10.7 | 1.8 |
| Kilgore Industries LP, Houston · 2019 | 565 | 0 | 0 | 0.0 | 1.8 |
| KIlgore Industries Houston · 2017 | 765 | 4 | 2 | 0.7 | 1.8 |
Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| Mar 2, 2025 to Feb 8, 2026 Houston | 33 | 26 | $8,292 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.150(c)(1)(i)
(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
29 CFR 1926.416(a)(1)
(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.