OSHA SearchOSHA records by employer

King Exteriors, LLC: OSHA inspections and violations

Meridian, Idaho · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
3citation items
$2,341current penalties
Oct 14, 2020last inspection

OSHA has inspected King Exteriors, LLC once in Idaho.

The inspection began on Oct 14, 2020 on a referral, in Meridian.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $2,341 and still stand at $2,341.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and King Exteriors, LLC averages $2,341 (1 cited inspection).

King Exteriors, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch King Exteriors, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344977855 OPENED OCT 14, 2020Closed

Referral · Partial · Safety · 7 employees at the site · Closed May 15, 2021

3624 N Center Point Way, Meridian, ID 83646 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,341$2,341Feb 10, 2021Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 10, 2021Final
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Feb 10, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.454(a)

(a) The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable:

Other new multifamily housing construction (except for-sale builders) employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.