OSHA SearchOSHA records by employer

Kirby Risk Corporation: OSHA inspections and violations

Lima, Ohio · Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers · NAICS 423610

1inspections
4citation items
$12,450current penalties
Feb 9, 2024last inspection

OSHA has inspected Kirby Risk Corporation once in Ohio.

The inspection began on Feb 9, 2024 on a referral, in Lima.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $20,742 and now stand at $12,450, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,424, and Kirby Risk Corporation averages $12,450 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Kirby Risk Corporation: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Kirby Risk Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Kirby Risk Corporation at 3 sites in 2 states. Together they've had 4 inspections and $18,666 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 3 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 347271496 OPENED FEB 9, 2024Closed

Referral · Partial · Safety · 15 employees at the site · Closed May 28, 2024

1249 Stewart Rd, Lima, OH 45801 · Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(l)(2)(ii) · Forklifts and other powered industrial trucks
Serious$11,524$6,925Apr 25, 2024Final
Citation 1, item 1b
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$0$0Apr 25, 2024Final
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$9,218$5,525Apr 25, 2024Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Apr 25, 2024Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 5, 2024, Lima: Hospitalization · fractures · rib(s), oblique area

On February 5, 2024, an employee was in a wire shipping basket supported/elevated by the forks of a powered industrial truck. The basket became displaced from the forks and the employee fell approximately 5 feet to the ground below and suffered multiple rib fractures.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(2)(ii)

(ii) Training shall consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace.

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

Other electrical apparatus and equipment, wiring supplies, and related equipment merchant wholesalers employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.