OSHA SearchOSHA records by employer

Kittell Builders, LLC: OSHA inspections and violations

Williston, Vermont · Framing Contractors · NAICS 238130

8inspections
8citation items
$3,975current penalties
Jul 1, 2015last inspection

Kittell Builders, LLC has 8 OSHA inspections on record in Vermont, the first in 1992.

OSHA's last visit started on Jul 1, 2015, in Essex.

Across those inspections OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

OSHA proposed $5,200 in penalties. After settlements and reviews the total is $3,975, down 24%.

Most often, OSHA cited 1926.501, fall protection in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Kittell Builders, LLC averages $1,000 over 1 cited inspection in that time.

Kittell Builders, LLC: OSHA citation items per year, 1992 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites Kittell Builders, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 340755164 OPENED JUL 1, 2015Closed

Unprogrammed other · Complete · Safety · 12 employees at the site · Closed Feb 2, 2016

9 Joshua Way, Essex, VT 05451 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$1,000Oct 6, 2015Final
Citation 2, item 1 Other-than-serious$0$0Oct 6, 2015Final

Inspection 311483390 OPENED OCT 21, 2009Closed

Referral · Partial · Safety · 6 employees at the site · Closed Nov 23, 2009

7 Joshua Way, Essex, VT 05451 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Other-than-serious$0$0Nov 10, 2009Closed

Inspection 311477277 OPENED APR 24, 2008Closed

Unprogrammed other · Complete · Safety · 11 employees at the site · Closed May 19, 2008

Day Lane, Williston, VT 05495 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$375$375May 8, 2008Closed

Inspection 308608223 OPENED NOV 28, 2006Closed

Unprogrammed other · Complete · Safety · 18 employees at the site · Closed Jan 19, 2007

2588 Blakely Road, Colchester, VT 05439 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$525$300Dec 27, 2006Closed
Citation 2, item 1
29 CFR 1926.501(c)(3) · Fall protection in construction
Other-than-serious$0$0Dec 27, 2006Closed

Inspection 305535064 OPENED FEB 5, 2004Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 17, 2004

Handy Suites, Essex Junction, VT 05451 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$2,000Mar 4, 2004Closed

Inspection 303450639 OPENED AUG 27, 2001Closed

Planned · Complete · Safety · 12 employees at the site · Closed Oct 10, 2001

303 Lime Kiln Road, South Burlington, VT 05401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$300$300Sep 19, 2001Closed

Inspection 302366471 OPENED APR 1, 1999Closed

Unprogrammed other · Partial · Safety · 14 employees at the site · Closed Apr 1, 1999

Williston Commons, Williston, VT 05495 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 111709747 OPENED AUG 20, 1992Closed

Planned · Complete · Safety · 5 employees at the site · Closed Aug 21, 1992

Wake Robin Way, Shelburne, VT 05482 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Vermont

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.