OSHA SearchOSHA records by employer

Kline Electric: OSHA inspections and violations

Ankeny, Iowa · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

15inspections
23citation items
$63,900current penalties
Oct 9, 2024last inspection

Since 2006, OSHA inspectors have visited Kline Electric in Iowa 15 times.

The most recent inspection opened on Oct 9, 2024, in Ames.

In all, OSHA issued 23 citation items: 18 serious, 1 repeat and 4 other-than-serious.

The proposed penalties came to $165,060; today they stand at $63,900, 61% less.

The rule cited most here is 1926.651 (excavations), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Kline Electric averages $25,300 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

Kline Electric also files yearly injury logs with OSHA, summarized below.

The Wage and Hour Division has 1 case on it since 2015, with $6,673 in back wages owed to workers.

Kline Electric: OSHA citation items per year, 2006 to 2024
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

64employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Kline Electric and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347807372 OPENED OCT 9, 2024Closed

Unprogrammed other · Complete · Safety · 4 employees at the site · Closed Nov 15, 2024

1025 S Dakota Ave, Ames, IA 50014 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347097727 OPENED NOV 9, 2023Closed

Complaint · Partial · Safety · 250 employees at the site · Closed Mar 13, 2024

110 W Washington St, Winterset, IA 50273 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345540371 OPENED SEP 20, 2021Closed

Unprogrammed other · Partial · Safety · 166 employees at the site · Closed Nov 23, 2021

6011 & 6015 Grand Ave, Des Moines, IA 50312 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344708060 OPENED MAR 23, 2020Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed May 7, 2020

115 Jackson Street, Brooklyn, IA 52211 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344014980 OPENED MAY 16, 2019Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jun 5, 2020

1005 8th St Sw, Altoona, IA 50009 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 15, 2019: One of two employees in trench cave-in is injured

At 10:00 a.m. on May 15, 2019, Employee #1 and his coworker, employed by a construction company, were working at the site of a new one-story commercial building. They were working in a trench that measured approximately 4 feet by 6 feet by 7 feet deep and trying to locate a buried conduit that powered two light fixtures. The trench walls were nearly vertical. Employee #1 was working on his knees and his coworker was standing on his feet when the south trench wall caved in. Employee #1 was buried to his shoulders, and his coworker was buried to his waist. The coworker had a shovel nearby and dug himself free, then proceeded to dig out Employee #1. The coworker then lifted Employee #1 by his rear side belt and helped lift him out of the trench. The coworker unhooked the mini excavator trailer from the pickup and drove Employee #1 to the hospital instead of calling for emergency services or summoning help from elsewhere on the jobsite. Employee #1 was admitted at the hospital and treated for a fractured clavicle, three fractured ribs, a collapsed lung, a punctured lung, and two fractured vertebrae. The coworker was uninjured.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$8,315$8,000Jul 24, 2019Final
Citation 1, item 2
29 CFR 1926.50(c) · Medical services and first aid
Serious$8,315$8,000Jul 24, 2019Final
Citation 1, item 3
29 CFR 1926.651(c)(2) · Excavations
Serious$8,315$8,000Jul 24, 2019Final
Citation 1, item 4
29 CFR 1926.651(i)(3) · Excavations
Serious$8,315$0Jul 24, 2019Final
Citation 1, item 5
29 CFR 1926.651(j)(2) · Excavations
Serious$8,315$0Jul 24, 2019Final
Citation 1, item 6
29 CFR 1926.651(k)(1) · Excavations
Serious$8,315$0Jul 24, 2019Final
Citation 1, item 7
29 CFR 1926.652(a)(1) · Trench protection
Serious$99,770$26,000Jul 24, 2019Final

Inspection 343054813 OPENED MAR 27, 2018Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Mar 27, 2018

2301 Sw Plaza Pkwy, Ankeny, IA 50023 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342799822 OPENED NOV 29, 2017Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Nov 30, 2017

2502 Se Tones Dr, Ankeny, IA 50021 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342368990 OPENED JUN 1, 2017Closed

Unprogrammed other · Partial · Safety · 2 employees at the site · Closed Jun 1, 2017

8711 Thomas Avenue, Johnston, IA 50131 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

7 older inspections

Inspection 341662088 OPENED JUL 25, 2016Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Dec 9, 2016

1218 South 4th Street, Ames, IA 50010 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$600$300Nov 14, 2016Final
Citation 1, item 2
29 CFR 1926.1060(b) · Ladder and stairway training
Serious$600$300Nov 14, 2016Final

Inspection 340457662 OPENED MAR 10, 2015Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Apr 13, 2015

6215 Nw 106th Street, Johnston, IA 50131 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340000025 OPENED OCT 9, 2014Closed

Unprogrammed other · Complete · Safety · 100 employees at the site · Closed Dec 12, 2014

2560,2580,2590 1st Ave Sw, Altoona, IA 50009 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$100$100Dec 5, 2014Final

Inspection 315546986 OPENED APR 6, 2011Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Jun 29, 2011

100 6th Street, Nevada, IA 50201 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$1,500$1,500May 9, 2011Closed
Citation 2, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Repeat$1,200$1,200May 9, 2011Closed
Citation 3, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$600$600May 9, 2011Closed

Inspection 315112540 OPENED NOV 10, 2010Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Jan 6, 2011

8789 Plum Drive, Urbandale, IA 50322 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$900$450Dec 10, 2010Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$900$450Dec 10, 2010Closed

Inspection 312624463 OPENED AUG 25, 2008Closed

Unprogrammed related · Complete · Safety · 4 employees at the site · Closed Oct 13, 2008

1690 S.e. Delaware, Ankeny, IA 50021 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310083225 OPENED NOV 9, 2006Closed

Accident · Complete · Safety · 11 employees at the site · Closed Feb 15, 2007

6301 University Avenue, Cedar Falls, IA 50613 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 8, 2006 (fatal): Employee electrocuted while wiring lighting system

On November 8, 2006, Employee #1, of Kline Electric,Inc., was wiring up a 277-vo lt permanent lighting system when he cut into an energized 277-volt emergency wi ring circuit. He was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$1,500$1,500Jan 10, 2007Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$1,500Jan 10, 2007Closed
Citation 1, item 3
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$1,500$1,500Jan 10, 2007Closed
Citation 1, item 4
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$1,500$1,500Jan 10, 2007Closed
Citation 1, item 5
29 CFR 1926.417(a) · Lockout and tagging of circuits
Serious$1,500$1,500Jan 10, 2007Closed
Citation 1, item 6
29 CFR 1926.417(b) · Lockout and tagging of circuits
Serious$1,500$1,500Jan 10, 2007Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 10, 2007Closed
Citation 2, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Jan 10, 2007Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Des Moines site logged 7 recordable injuries or illnesses among about 271 workers: 2.6 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Team Kline Des Moines
Des Moines · 2025
271 702.61.8
Kline Electric
Des Moines · 2022
217 1135.11.8

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Jul 30, 2018 to Jan 31, 2019
Des Moines
2514$6,673$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.417 · Lockout and tagging of circuits

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.