OSHA SearchOSHA records by employer

KMS Fab, LLC: OSHA inspections and violations

Luzerne, Pennsylvania · Sheet Metal Work Manufacturing · NAICS 332322

4inspections
12citation items
$8,534current penalties
Dec 3, 2018last inspection

KMS Fab, LLC has 4 OSHA inspections on record in Pennsylvania, the first in 2010.

OSHA's last visit started on Dec 3, 2018 as a planned inspection, in Luzerne.

Across those inspections OSHA issued 12 citation items: 9 serious and 3 other-than-serious.

OSHA proposed $13,417 in penalties. After settlements and reviews the total is $8,534, down 36%.

Most often, OSHA cited 1910.107, spray painting and finishing (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. KMS Fab, LLC averages $0 over 1 cited inspection in that time.

KMS Fab, LLC also files yearly injury logs with OSHA, summarized below.

KMS Fab, LLC: OSHA citation items per year, 2010 to 2018
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch KMS Fab, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343633947 OPENED DEC 3, 2018Closed

Planned · Partial · Health · 52 employees at the site · Closed Dec 28, 2018

100 Parry Street, Luzerne, PA 18709 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340167642 OPENED JAN 8, 2015Closed

Referral · Partial · Health · 36 employees at the site · Closed Sep 11, 2015

100 Parry Street, Luzerne, PA 18709 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Apr 30, 2015Final

Inspection 340125558 OPENED DEC 8, 2014Closed

Planned · Complete · Safety · 47 employees at the site · Closed Aug 4, 2015

100 Parry Street, Luzerne, PA 18709 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$3,570$2,499May 8, 2015Final
Citation 1, item 1b
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$0$0May 8, 2015Final
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0May 8, 2015Final
Citation 1, item 1d
29 CFR 1910.107(h)(12) · Spray painting and finishing
Serious$0$0May 8, 2015Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,380$1,666May 8, 2015Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,785$1,250May 8, 2015Final
Citation 2, item 1
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$1,517$0May 8, 2015Final

Inspection 314159740 OPENED NOV 17, 2010Closed

Planned · Partial · Safety · 55 employees at the site · Closed Jun 21, 2011

100 Parry St., Luzerne, PA 18709 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,380$1,785Jan 20, 2011Closed
Citation 1, item 1b
29 CFR 1910.212(a)(1) · Machine guarding
Serious$0$0Jan 20, 2011Closed
Citation 1, item 2
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$1,785$1,335Jan 20, 2011Closed
Citation 2, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Jan 20, 2011Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Luzerne site logged 0 recordable injuries or illnesses among about 56 workers: 0.0 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
KMS Fab LLC
Luzerne · 2023
56 000.02.4

Included with any plan: 7 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

Other sheet metal work manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.