OSHA SearchOSHA records by employer

Koch Konstruction, Inc.: OSHA inspections and violations

Morton, Illinois · Roofing Contractors · NAICS 238160

8inspections
36citation items
$26,347current penalties
Nov 22, 2016last inspection

Koch Konstruction, Inc. has 8 OSHA inspections on record in Illinois, the first in 2003.

OSHA's last visit started on Nov 22, 2016 after a complaint, in Morton.

Across those inspections OSHA issued 36 citation items: 27 serious, 2 willful, 5 repeat and 2 other-than-serious.

OSHA proposed $51,755 in penalties. After settlements and reviews the total is $26,347, down 49%.

Most often, OSHA cited 1926.501, fall protection in construction (7 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Koch Konstruction, Inc. averages $7,250 over 2 cited inspections in that time.

Koch Konstruction, Inc.: OSHA citation items per year, 2003 to 2016
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

155 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Koch Konstruction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341930642 OPENED NOV 22, 2016Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Feb 3, 2017

200 Jadewood, Morton, IL 61550 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,940$1,000Jan 11, 2017Final
Citation 1, item 1b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Jan 11, 2017Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,115$2,500Jan 11, 2017Final

Inspection 340823889 OPENED AUG 4, 2015Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Sep 24, 2015

200 E. Fast Ave, Mackinaw, IL 61755 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Willful$11,000$11,000Aug 26, 2015Final
Citation 1, item 1b
29 CFR 1926.501(b)(11) · Fall protection in construction
Willful$14,000$0Aug 26, 2015Final

Inspection 339761017 OPENED MAY 6, 2014Closed

Planned · Partial · Safety · 4 employees at the site · Closed May 6, 2014

1133 N Main St, Washington, IL 61571 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312889785 OPENED OCT 22, 2009Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Oct 22, 2009

1217 Linden, Morton, IL 61550 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312888928 OPENED SEP 2, 2009Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 23, 2011

30930 Fast Ave, Mackinaw, IL 61755 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$600$302Sep 15, 2009Closed
Citation 1, item 1b
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Sep 15, 2009Closed
Citation 1, item 2a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,000$1,000Sep 15, 2009Closed
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 15, 2009Closed
Citation 1, item 2c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Sep 15, 2009Closed
Citation 1, item 3
29 CFR 1926.452(k)(5) · Rules for each type of scaffold
Serious$2,000$1,000Sep 15, 2009Closed
Citation 2, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,000$2,400Sep 15, 2009Closed
Citation 2, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$0$0Sep 15, 2009Closed
Citation 2, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$0$0Sep 15, 2009Closed

Inspection 312885015 OPENED FEB 6, 2009Closed

Planned · Partial · Safety · 3 employees at the site · Closed Apr 3, 2009

111/113 Crestwood Street, Morton, IL 61550 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$750$450Feb 12, 2009Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Feb 12, 2009Closed
Citation 1, item 2a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$750$450Feb 12, 2009Closed
Citation 1, item 2b
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$0$0Feb 12, 2009Closed
Citation 1, item 3a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,050$600Feb 12, 2009Closed
Citation 1, item 3b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Feb 12, 2009Closed
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Feb 12, 2009Closed

Inspection 308568682 OPENED SEP 21, 2005Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Oct 21, 2005

Akron Ct., Morton, IL 61550 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$1,200$500Sep 23, 2005Closed
Citation 2, item 1b
29 CFR 1926.503(a)(2) · Fall protection training in construction
Repeat$0$0Sep 23, 2005Closed

Inspection 305892580 OPENED DEC 22, 2003Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Mar 8, 2004

Tremont Community Bldg., 521 South Sampson Street, Tremont, IL 61568 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$1,050Feb 2, 2004Closed
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Feb 2, 2004Closed
Citation 1, item 1c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Feb 2, 2004Closed
Citation 1, item 1d
29 CFR 1926.503(a)(2) · Fall protection training in construction
Serious$0$0Feb 2, 2004Closed
Citation 1, item 2a
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$420Feb 2, 2004Closed
Citation 1, item 2b
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$0$0Feb 2, 2004Closed
Citation 1, item 3a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$750$525Feb 2, 2004Closed
Citation 1, item 3b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Feb 2, 2004Closed
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,500$1,050Feb 2, 2004Closed
Citation 1, item 5
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,050Feb 2, 2004Closed
Citation 1, item 6a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,500$1,050Feb 2, 2004Closed
Citation 1, item 6b
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$0$0Feb 2, 2004Closed
Citation 2, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Feb 2, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.