OSHA SearchOSHA records by employer

Kongsberg Protech Systems USA: OSHA inspections and violations

Johnstown, Pennsylvania · Military Armored Vehicle, Tank, and Tank Component Manufacturing · NAICS 336992

1inspections
4citation items
$6,650current penalties
Oct 3, 2019last inspection

OSHA has inspected Kongsberg Protech Systems USA once in Pennsylvania.

The inspection began on Oct 3, 2019 as a planned inspection, in Johnstown.

That inspection ended with 4 citation items: 2 serious and 2 other-than-serious.

Penalties were first proposed at $10,230 and now stand at $6,650, 35% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Kongsberg Protech Systems USA averages $6,650 (1 cited inspection).

Kongsberg Protech Systems USA also files yearly injury logs with OSHA, summarized below.

Kongsberg Protech Systems USA: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Kongsberg Protech Systems USA and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344355011 OPENED OCT 3, 2019Closed

Planned · Partial · Health · 180 employees at the site · Closed Nov 22, 2019

210 Industrial Park Road, Johnstown, PA 15904 · Military Armored Vehicle, Tank, and Tank Component Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$5,115$3,325Oct 22, 2019Final
Citation 1, item 2
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$5,115$3,325Oct 22, 2019Final
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Oct 22, 2019Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Oct 22, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Johnstown site logged 2 recordable injuries or illnesses among about 247 workers: 1.1 per 100 full-time workers, against a median of 2.1 for its industry. Those cases cost 180 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Johnstown site
Johnstown · 2024
247 211.12.1
Kongsberg Protech Systems USA Johnstown
Johnstown · 2021
180 301.82.1

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.133(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

Other military armored vehicle, tank, and tank component manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.