OSHA SearchOSHA records by employer

Koppy Motors, Inc.: OSHA inspections and violations

Youngtown, Arizona · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

4inspections
19citation items
$2,250current penalties
Sep 10, 2015last inspection

Since 1988, OSHA inspectors have visited Koppy Motors, Inc. in Arizona 4 times.

The most recent inspection opened on Sep 10, 2015 as a planned inspection, in Youngtown.

In all, OSHA issued 19 citation items: 9 serious and 10 other-than-serious.

The penalties, $2,250 in total, stand where OSHA first set them.

The rule cited most here is 1910.1200 (hazard communication), 4 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Koppy Motors, Inc. averages $2,250 across 1 cited inspection.

Koppy Motors, Inc.: OSHA citation items per year, 1988 to 2015
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

80employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Koppy Motors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340911718 OPENED SEP 10, 2015Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jan 26, 2016

11202 W Michigan Ave, Youngtown, AZ 85363 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR A.R.S. 23-403.A
Serious$750$750Nov 30, 2015Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$600$600Nov 30, 2015Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Nov 30, 2015Final
Citation 1, item 2c
29 CFR 1910.134(k) · Respiratory protection
Serious$0$0Nov 30, 2015Final
Citation 1, item 3a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$450$450Nov 30, 2015Final
Citation 1, item 3b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Nov 30, 2015Final
Citation 1, item 3c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Nov 30, 2015Final
Citation 1, item 4a
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$450$450Nov 30, 2015Final
Citation 1, item 4b
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 30, 2015Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Nov 30, 2015Final
Citation 2, item 2
29 CFR 1910.303(g)(1)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 30, 2015Final
Citation 2, item 3
29 CFR 1910.1200(f)(9) · Hazard communication
Other-than-serious$0$0Nov 30, 2015Final

Inspection 103774741 OPENED JUN 20, 1989Closed

Follow-up · Partial · Health · 12 employees at the site · Closed Jun 28, 1989

11202 Michigan Avenue, Youngtown, AZ 85363 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 103774295 OPENED DEC 28, 1988Closed

Follow-up · Partial · Health · 12 employees at the site · Closed Jun 28, 1989

11202 Michigan Avenue, Youngtown, AZ 85363 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 103774055 OPENED SEP 28, 1988Closed

Planned · Complete · Health · 12 employees at the site · Closed Jun 28, 1989

11202 Michigan Avenue, Youngtown, AZ 85363 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 2
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 3
29 CFR 1910.107(c)(8) · Spray painting and finishing
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 5
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 6
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 7
29 CFR R4130631 A
Other-than-serious$0$0Oct 17, 1988Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(c)(8)

(8) Portable lamps. Portable electric lamps shall not be used in any spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, shall be of the type approved for hazardous Class I locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

Other automotive body, paint, and interior repair and maintenance employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.