KWW Enterprises LLC: OSHA inspections and violations

Corpus Christi, Texas · Finish Carpentry Contractors · NAICS 238350

1inspections
5citation items
$5,200current penalties
Apr 11, 2016last inspection

OSHA inspectors have visited KWW Enterprises LLC in Texas one time.

It opened on Apr 11, 2016 as a planned inspection, in Corpus Christi.

In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

The penalties, $5,200 in total, stand where OSHA first set them.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. KWW Enterprises LLC averages $5,200 across 1 cited inspection.

KWW Enterprises LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch KWW Enterprises LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341397222 OPENED APR 11, 2016Closed

Planned · Partial · Health · 6 employees at the site · Closed Nov 26, 2019

3511 South Padre Island Dr, Corpus Christi, TX 78415 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$2,800$2,800Jul 29, 2016Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$1,200$1,200Jul 29, 2016Final
Citation 1, item 3a
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$1,200$1,200Jul 29, 2016Final
Citation 1, item 3b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jul 29, 2016Final
Citation 2, item 1
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Jul 29, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.242(b)

(b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(7)(i)

(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.

29 CFR 1910.95 · Noise

Other finish carpentry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.