OSHA SearchOSHA records by employer

L & L Erectors Inc: OSHA inspections and violations

Bloomington, Indiana · Other Foundation, Structure, and Building Exterior Contractors · NAICS 238190

4inspections
16citation items
$8,224current penalties
Dec 19, 2023last inspection

OSHA has inspected L & L Erectors Inc 4 times in Indiana since 2008.

The latest one began on Dec 19, 2023 on a referral, in Lafayette.

Those inspections ended with 16 citation items: 15 serious and 1 other-than-serious.

Penalties were first proposed at $10,450 and now stand at $8,224, 21% lower after settlements or reviews.

Fall protection systems comes up most often in these citations: 5 items under 1926.502.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and L & L Erectors Inc averages $1,437 (1 cited inspection).

L & L Erectors Inc: OSHA citation items per year, 2008 to 2023
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch L & L Erectors Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347180333 OPENED DEC 19, 2023Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jun 6, 2024

4877 E Old Cr 350 S, Lafayette, IN 47901 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317865640 OPENED MAY 13, 2015Closed

Unprogrammed other · Complete · Safety · 13 employees at the site · Closed Aug 17, 2015

1100 N Lebanon St, Jamestown, IN 46147 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(d)(2) · Flammable liquids
Serious$800$296Jul 7, 2015Closed
Citation 1, item 2
29 CFR 1926.152(e)(4) · Flammable liquids
Serious$2,000$845Jul 7, 2015Closed
Citation 1, item 3
29 CFR 1926.152(g)(9) · Flammable liquids
Serious$600$296Jul 7, 2015Closed

Inspection 317451631 OPENED MAR 18, 2014Closed

Referral · Partial · Safety · 4 employees at the site · Closed Aug 20, 2014

6650 Bluff Road, Indianapolis, IN 46217 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$600$600Jul 17, 2014Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Jul 17, 2014Closed
Citation 1, item 2
29 CFR 1926.20(b)(3) · Construction safety programs
Serious$600$600Jul 17, 2014Closed
Citation 1, item 3
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$1,500$1,500Jul 17, 2014Closed
Citation 1, item 4a
29 CFR 1926.454(a) · Scaffold training
Serious$600$600Jul 17, 2014Closed
Citation 1, item 4b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Jul 17, 2014Closed
Citation 1, item 5
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,500$1,500Jul 17, 2014Closed
Citation 1, item 6
29 CFR 1926.502(d)(11) · Fall protection systems
Serious$750$750Jul 17, 2014Closed
Citation 1, item 7a
29 CFR 1926.502(f)(2)(ii) · Fall protection systems
Serious$750$750Jul 17, 2014Closed
Citation 1, item 7b
29 CFR 1926.502(f)(2)(v) · Fall protection systems
Serious$0$0Jul 17, 2014Closed

Inspection 312094360 OPENED AUG 20, 2008Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Oct 22, 2008

4841 West Vernal Pike, Bloomington, IN 47404 · Other Foundation, Structure, and Building Exterior Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$375$244Sep 30, 2008Closed
Citation 1, item 2
29 CFR 1926.502(f)(1)(iii) · Fall protection systems
Serious$375$244Sep 30, 2008Closed
Citation 2, item 1
29 CFR 1926.502(f)(2)(i) · Fall protection systems
Other-than-serious$0$0Sep 30, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.152(d)(2)

(2) At least one portable fire extinguisher having a rating of not less than 20-B units shall be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside.

29 CFR 1926.152(e)(4)

(4) The dispensing units shall be protected against collision damage.

29 CFR 1926.152(g)(9)

(9) Conspicuous and legible signs prohibiting smoking shall be posted.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other other foundation, structure, and building exterior contractors employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.