OSHA SearchOSHA records by employer

L & M Masonry, LLC: OSHA inspections and violations

Birmingham, Alabama · Masonry Contractors · NAICS 238140

3inspections
17citation items
$11,246current penalties
Aug 6, 2015last inspection

Since 1997, OSHA inspectors have visited L & M Masonry, LLC in Alabama 3 times.

The most recent inspection opened on Aug 6, 2015, in Bessemer.

In all, OSHA issued 17 citation items: 13 serious and 4 other-than-serious.

The proposed penalties came to $19,946; today they stand at $11,246, 44% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 12 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. L & M Masonry, LLC averages $1,496 across 1 cited inspection.

L & M Masonry, LLC: OSHA citation items per year, 1997 to 2015
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

95employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch L & M Masonry, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340832757 OPENED AUG 6, 2015Closed

Unprogrammed other · Complete · Safety · 13 employees at the site · Closed Jun 7, 2019

100 14th Street South, Bessemer, AL 35020 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,496$1,496Oct 5, 2015Final
Citation 2, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Oct 5, 2015Final
Citation 2, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Other-than-serious$0$0Oct 5, 2015Final
Citation 2, item 3
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Other-than-serious$0$0Oct 5, 2015Final

Inspection 315509620 OPENED JUN 2, 2011Closed

Planned · Complete · Safety · 10 employees at the site · Closed Nov 4, 2013

98 Summerall Gate Road, Anniston, AL 36201 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,000$1,500Sep 30, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(b)(5)(i) · Scaffolds, general requirements
Serious$0$0Sep 30, 2011Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,000$1,500Sep 30, 2011Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,200$2,100Sep 30, 2011Closed
Citation 1, item 4
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,000$1,500Sep 30, 2011Closed

Inspection 300960796 OPENED AUG 20, 1997Closed

Unprogrammed related · Complete · Safety · 50 employees at the site · Closed Nov 12, 1997

1400 Bankhead Highway West, Birmingham, AL 35204 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(15) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 1, item 3
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 1, item 4
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 1, item 5a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 1, item 5b
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Sep 15, 1997Closed
Citation 1, item 6
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$875$525Sep 15, 1997Closed
Citation 2, item 1
29 CFR 1926.454(b)(2) · Scaffold training
Other-than-serious$0$0Sep 15, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(k)(6)

(6) The basic advisory information on respirators, as presented in appendix D of this section, shall be provided by the employer in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(15)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.