OSHA SearchOSHA records by employer

L. Holzner Electric Company: OSHA inspections and violations

Bridgeport, Connecticut · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
6citation items
$9,760current penalties
Oct 12, 2023last inspection

L. Holzner Electric Company has 2 OSHA inspections on record in Connecticut, the first in 2012.

OSHA's last visit started on Oct 12, 2023 on a referral, in Harwinton.

Across those inspections OSHA issued 6 citation items: 5 serious and 1 other-than-serious.

OSHA proposed $14,837 in penalties. After settlements and reviews the total is $9,760, down 34%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. L. Holzner Electric Company averages $5,000 over 1 cited inspection in that time.

L. Holzner Electric Company: OSHA citation items per year, 2012 to 2023
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

87employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch L. Holzner Electric Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347029845 OPENED OCT 12, 2023Closed

Referral · Partial · Safety · 24 employees at the site · Closed Jun 4, 2024

34 Connecticut Route 4 (ct-4) 1 Harwinton Heights Road, Harwinton, CT 06791 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$4,465$3,000Jan 8, 2024Final
Citation 1, item 1b
29 CFR 1910.67(c)(2)(ii) · Vehicle-mounted elevating and rotating work platforms
Serious$0$0Jan 8, 2024Final
Citation 1, item 2
29 CFR 1910.135(a)(2) · Head protection
Serious$3,572$2,000Jan 8, 2024Final

Inspection 336255781 OPENED AUG 7, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed Aug 29, 2013

Cannon Street @ Broad Street, Bridgeport, CT 06604 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,000$1,400Sep 12, 2012Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Other-than-serious$2,000$1,400Sep 12, 2012Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$1,960Sep 12, 2012Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.135 · Head protection

29 CFR 1910.135(a)(2)

(2) The employer shall ensure that a protective helmet designed to reduce electrical shock hazard is worn by each such affected employee when near exposed electrical conductors which could contact the head.

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(ii)

(ii) Only trained persons shall operate an aerial lift.

29 CFR 1910.67(c)(2)(v)

(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.