OSHA SearchOSHA records by employer

Lake Iron Inc.: OSHA inspections and violations

Chicago, Illinois · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
28citation items
$17,897current penalties
Oct 11, 2018last inspection

Since 2006, OSHA inspectors have visited Lake Iron Inc. in Illinois 5 times.

The most recent inspection opened on Oct 11, 2018 as a planned inspection, in Chicago.

In all, OSHA issued 28 citation items: 25 serious, 1 repeat and 2 other-than-serious.

The proposed penalties came to $31,262; today they stand at $17,897, 43% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lake Iron Inc. averages $7,372 across 1 cited inspection.

Lake Iron Inc.: OSHA citation items per year, 2006 to 2018
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

416employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Lake Iron Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343526620 OPENED OCT 11, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed Nov 27, 2019

1300 N. Claremont Ave., Chicago, IL 60622 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,880$2,716Dec 11, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,880$2,716Dec 11, 2018Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,772$1,940Dec 11, 2018Final

Inspection 334142429 OPENED MAY 3, 2012Closed

Planned · Partial · Safety · 7 employees at the site · Closed Feb 14, 2013

1140 Garfield St., Oak Park, IL 60304 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.251(a)(2)(i) · Rigging equipment for material handling
Serious$1,600$800Jun 8, 2012Final
Citation 1, item 1b
29 CFR 1926.251(e)(8) · Rigging equipment for material handling
Serious$0$0Jun 8, 2012Final
Citation 1, item 2a
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$1,600$800Jun 8, 2012Final
Citation 1, item 2b
29 CFR 1926.351(d)(1) · Arc welding and cutting
Serious$0$0Jun 8, 2012Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,800$1,360Jun 8, 2012Final
Citation 1, item 4a
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$2,000$1,000Jun 8, 2012Final
Citation 1, item 4b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Jun 8, 2012Final
Citation 1, item 4c
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Jun 8, 2012Final
Citation 1, item 5a
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$2,800$1,400Jun 8, 2012Final
Citation 1, item 5b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 8, 2012Final
Citation 1, item 5c
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$0$0Jun 8, 2012Final
Citation 1, item 6
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,000$1,000Jun 8, 2012Final
Citation 1, item 7
29 CFR 1926.760(d)(1) · Fall protection
Serious$2,000$1,000Jun 8, 2012Final
Citation 1, item 8
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,600$800Jun 8, 2012Final
Citation 2, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Other-than-serious$0$0Jun 8, 2012Final
Citation 2, item 2
29 CFR 1926.352(d) · Fire prevention
Other-than-serious$0$0Jun 8, 2012Final
Citation 2, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Repeat$80$80Jun 8, 2012Final

Inspection 314033416 OPENED JAN 22, 2010Closed

Planned · Complete · Health · 4 employees at the site · Closed Mar 29, 2010

Root Street And Galena Street, Auora, IL 60505 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$800$560Feb 26, 2010Closed

Inspection 311376347 OPENED AUG 25, 2008Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 27, 2008

8100 S. Stony Island Ave., Chicago, IL 60617 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309030211 OPENED APR 24, 2006Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jun 28, 2006

1618 South Halsted Street, Chicago, IL 60608 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$450$225Jun 13, 2006Closed
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Serious$450$225Jun 13, 2006Closed
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$525Jun 13, 2006Closed
Citation 1, item 3b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 13, 2006Closed
Citation 1, item 3c
29 CFR 1926.454(a)(1) · Scaffold training
Serious$0$0Jun 13, 2006Closed
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$750$375Jun 13, 2006Closed
Citation 1, item 5
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$750$375Jun 13, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.352 · Fire prevention

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.760 · Fall protection

Other structural steel and precast concrete contractors employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.