OSHA SearchOSHA records by employer

Lantz Elite Carpentry & Construction, Inc.: OSHA inspections and violations

Ankeny, Iowa · Framing Contractors · NAICS 238130

8inspections
23citation items
$19,395current penalties
Apr 18, 2025last inspection

OSHA has inspected Lantz Elite Carpentry & Construction, Inc. 8 times in Iowa since 2011.

The latest one began on Apr 18, 2025, in Ankeny.

Those inspections ended with 23 citation items: 6 serious and 17 other-than-serious.

Penalties were first proposed at $31,209 and now stand at $19,395, 38% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Lantz Elite Carpentry & Construction, Inc. averages $5,625 (3 cited inspections).

Lantz Elite Carpentry & Construction, Inc.: OSHA citation items per year, 2011 to 2025
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Lantz Elite Carpentry & Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348181363 OPENED APR 18, 2025Closed

Programmed other · Partial · Safety · 3 employees at the site · Closed Nov 19, 2025

Ne 55th Ln. And Ne Lavender Ln., Ankeny, IA 50021 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$2,232$1,600Jul 11, 2025Final
Citation 1, item 2
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$2,232$1,600Jul 11, 2025Final
Citation 1, item 3
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$1,339$1,600Jul 11, 2025Final
Citation 1, item 4
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Other-than-serious$2,232$1,600Jul 11, 2025Final
Citation 1, item 5
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Other-than-serious$3,125$1,600Jul 11, 2025Final
Citation 1, item 6
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$1,786$500Jul 11, 2025Final

Inspection 346417199 OPENED JAN 4, 2023Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Feb 17, 2023

655 South 88th Street #2000 And #5000, West Des Moines, IA 50266 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344373790 OPENED OCT 9, 2019Closed

Planned · Complete · Safety · 1 employee at the site · Closed Dec 2, 2019

705 Se Gateway Drive, Grimes, IA 50111 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343057683 OPENED MAR 14, 2018Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed Oct 18, 2018

4415 Lincoln Way, Ames, IA 50010 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 13, 2018: Two employees incur fractures when stairs collapses

At 11:15 a.m. on March 13, 2018, Employees #1 and #2, employed by a construction company, were working at a multiemployer construction project, a four-story multifamily residential building. They were descending a stairway when the stairway collapsed. Both employees fell, a fall height of 17 feet. Emergency services were called, and the employees were transported to the hospital, where both were admitted. Employee #1 was treated for a fractured pelvis. Employee #2 was treated for a fractured ankle.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 88.4 - CODE OF IOWA (2017)
Other-than-serious$4,988$3,500Apr 17, 2018Final

Inspection 342912995 OPENED JAN 30, 2018Closed

Unprogrammed other · Partial · Safety · 1 employee at the site · Closed Feb 6, 2018

4415 Lincoln Way, Ames, IA 50014 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342799707 OPENED NOV 29, 2017Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Nov 30, 2017

2502 Se Tones Dr, Ankeny, IA 50021 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342111200 OPENED FEB 14, 2017Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Dec 14, 2017

132 E. Center Street, Des Moines, IA 50309 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$525$525Mar 23, 2017Final
Citation 1, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$525$525Mar 23, 2017Final
Citation 1, item 3
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$300$300Mar 23, 2017Final
Citation 1, item 4
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,500$1,500Mar 23, 2017Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$1,500Mar 23, 2017Final
Citation 1, item 6
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$525$525Mar 23, 2017Final

Inspection 315489740 OPENED MAR 23, 2011Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Sep 6, 2011

460 Se Brick Drive - Se Jonas Circle Units 1-90, Waukee, IA 50263 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$600$180May 9, 2011Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$600$180May 9, 2011Closed
Citation 1, item 3
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$750$225May 9, 2011Closed
Citation 1, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$1,050$315May 9, 2011Closed
Citation 1, item 5
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$1,050$315May 9, 2011Closed
Citation 1, item 6
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$1,500$450May 9, 2011Closed
Citation 1, item 7
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$750$225May 9, 2011Closed
Citation 1, item 8
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Other-than-serious$750$225May 9, 2011Closed
Citation 1, item 9
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$600$180May 9, 2011Closed
Citation 1, item 10
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$750$225May 9, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.25 · Housekeeping

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other framing contractors employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.