OSHA SearchOSHA records by employer

Lantz Masonry - Concrete LLC: OSHA inspections and violations

Minneapolis, Minnesota · Masonry Contractors · NAICS 238140

2inspections
2citation items
$840current penalties
Aug 17, 2020last inspection

Lantz Masonry - Concrete LLC has 2 OSHA inspections on record in Minnesota, the first in 2016.

OSHA's last visit started on Aug 17, 2020 after a complaint, in Red Wing.

Across those inspections OSHA issued 2 citation items: 2 serious.

OSHA proposed $1,200 in penalties. After settlements and reviews the total is $840, down 30%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Lantz Masonry - Concrete LLC averages $840 over 1 cited inspection in that time.

Lantz Masonry - Concrete LLC: OSHA citation items per year, 2016 to 2020
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Lantz Masonry - Concrete LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344888656 OPENED AUG 17, 2020Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Nov 13, 2020

540 Tyler Rd S, Red Wing, MN 55066 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$525$368Oct 13, 2020Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$675$472Oct 13, 2020Final

Inspection 341841898 OPENED OCT 13, 2016Closed

Planned · Complete · Health · 4 employees at the site · Closed Nov 15, 2016

1103 West Lake Street, Minneapolis, MN 55408 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other masonry contractors employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.