OSHA SearchOSHA records by employer

Lariviere, Inc.: OSHA inspections and violations

Post Falls, Idaho · Poured Concrete Foundation and Structure Contractors · NAICS 238110

10inspections
12citation items
$36,902current penalties
Oct 16, 2024last inspection

Since 2019, OSHA inspectors have visited Lariviere, Inc. in Idaho 10 times.

The most recent inspection opened on Oct 16, 2024 on a referral, in Nampa.

In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

The proposed penalties came to $53,656; today they stand at $36,902, 31% less.

The rule cited most here is 1926.652 (trench protection), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lariviere, Inc. averages $12,301 across 3 cited inspections.

Lariviere, Inc.: OSHA citation items per year, 2019 to 2024
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch Lariviere, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347849333 OPENED OCT 16, 2024Closed

Referral · Partial · Safety · 14 employees at the site · Closed Feb 19, 2025

Industrial Road, Nampa, ID 83687 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347596827 OPENED JUL 2, 2024Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Nov 21, 2024

Chinden Blvd Between Maple Grove Rd And Coffey St, Boise, ID 83714 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$11,409$8,557Sep 25, 2024Final
Citation 1, item 2a
29 CFR 1926.651(k)(1) · Excavations
Other-than-serious$9,126$6,845Sep 25, 2024Final
Citation 1, item 2b
29 CFR 1926.652(a)(1) · Trench protection
Other-than-serious$0$0Sep 25, 2024Final

Inspection 347502635 OPENED MAY 23, 2024Closed

Planned · Partial · Safety · 6 employees at the site · Closed Jun 7, 2024

Us 95, Ponderay, ID 83852 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347420747 OPENED APR 3, 2024Closed

Planned · No inspection · Safety · 1 employee at the site · Closed Apr 3, 2024

Unknown, Bayview, ID 83803 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347376717 OPENED MAR 19, 2024Closed

Planned · No inspection · Safety · 1 employee at the site · Closed Mar 19, 2024

Various Locations, Boise, ID · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346115827 OPENED AUG 1, 2022Closed

Referral · Complete · Safety · 150 employees at the site · Closed Jul 5, 2023

Wildflower Meadows Corner Of Midway & Mcguire, Post Falls, ID 83854 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.251(a)(1) · Rigging equipment for material handling
Serious$8,036$6,250Jan 26, 2023Final
Citation 1, item 1b
29 CFR 1926.251(a)(2)(i) · Rigging equipment for material handling
Serious$0$0Jan 26, 2023Final
Citation 1, item 2a
29 CFR 1926.652(g)(1)(ii) · Trench protection
Serious$8,036$6,250Jan 26, 2023Final
Citation 1, item 2b
29 CFR 1926.652(g)(1)(iii) · Trench protection
Serious$0$0Jan 26, 2023Final

Inspection 346133424 OPENED AUG 1, 2022Closed

Unprogrammed related · Partial · Health · 150 employees at the site · Closed Jan 19, 2023

Wildflower Meadows Corner Of Midway & Mcguire, Post Falls, ID 83854 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345297741 OPENED MAY 5, 2021Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Aug 5, 2021

801 Ontario Street, Sandpoint, ID 83864 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

2 older inspections

Inspection 345152516 OPENED FEB 3, 2021Closed

Planned · Partial · Safety · 106 employees at the site · Closed Mar 3, 2021

Hwy 41 And 12th Ave, Post Falls, ID 83854 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343773768 OPENED JAN 31, 2019Closed

Unprogrammed other · Partial · Safety · 200 employees at the site · Closed Jun 27, 2019

201 N 1st Ave, Coeur D Alene, ID 83815 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.25(a) · Housekeeping
Serious$5,115$2,700Mar 26, 2019Final
Citation 1, item 1b
29 CFR 1926.34(c) · Means of egress
Serious$0$0Mar 26, 2019Final
Citation 1, item 2a
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$5,115$2,700Mar 26, 2019Final
Citation 1, item 2b
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Mar 26, 2019Final
Citation 1, item 3
29 CFR 1926.502(b)(13) · Fall protection systems
Serious$6,819$3,600Mar 26, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.251(a)(1)

(a) General. (1) Rigging equipment for material handling shall be inspected prior to use on each shift and as necessary during its use to ensure that it is safe. Defective rigging equipment shall be removed from service.

29 CFR 1926.251(a)(2)(i)

(i) Has permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load;

29 CFR 1926.34 · Means of egress

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

OSH Act Section 5 · General Duty Clause

Other poured concrete foundation and structure contractors employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.