OSHA SearchOSHA records by employer

Lec Properties, Inc.: OSHA inspections and violations

Jamestown, North Carolina · Commercial and Institutional Building Construction · NAICS 236220

4inspections
5citation items
$3,576current penalties
Sep 11, 2025last inspection

Since 1995, OSHA inspectors have visited Lec Properties, Inc. in North Carolina 4 times.

The most recent inspection opened on Sep 11, 2025 as a planned inspection, in Jamestown.

In all, OSHA issued 5 citation items: 1 serious and 4 other-than-serious.

The penalties, $3,576 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lec Properties, Inc. averages $3,226 across 1 cited inspection.

Lec Properties, Inc.: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

237employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Lec Properties, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348501206 OPENED SEP 11, 2025Closed

Planned · Partial · Safety · 12 employees at the site · Closed Oct 22, 2025

4818 W. Wendover Ave, Jamestown, NC 27282 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 348015132 OPENED JAN 29, 2025Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jul 14, 2025

4818 W. Wendover Ave, Jamestown, NC 27282 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$3,226$3,226May 5, 2025Final

Inspection 345895114 OPENED APR 13, 2022Closed

Complaint · Partial · Safety · 5 employees at the site · Closed May 3, 2022

2021 Honeycutt Drive, Durham, NC 27701 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125241943 OPENED FEB 27, 1995Closed

Referral · Complete · Safety · 3 employees at the site · Closed Mar 7, 1996

101a Cambridge Park Plaza, Winston-salem, NC 27104 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$250$250Mar 28, 1995Closed
Citation 2, item 1
29 CFR 1903.2(a)(1) · Posting of notice; availability of the Act, regulations and applicable standards
Other-than-serious$100$100Mar 28, 1995Closed
Citation 2, item 2
29 CFR 1926.50(f) · Medical services and first aid
Other-than-serious$0$0Mar 28, 1995Closed
Citation 2, item 3
29 CFR 1926.1052(c)(1) · Stairways in construction
Other-than-serious$0$0Mar 28, 1995Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.2 · Posting of notice; availability of the Act, regulations and applicable standards

29 CFR 1903.2(a)(1)

(a)(1) Each employer shall post and keep posted a notice or notices, to be furnished by the Occupational Safety and Health Administration, U.S. Department of Labor, informing employees of the protections and obligations provided for in the Act, and that for assistance and information, including copies of the Act and of specific safety and health standards, employees should contact the employer or the nearest office of the Department of Labor. Such notice or notices shall be posted by the employer in each establishment in a conspicuous place or places where notices to employees are customarily posted. Each employer shall take steps to insure that such notices are not altered, defaced, or covered by other material.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

Other commercial and institutional building construction employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.