OSHA SearchOSHA records by employer

Lee County Electric Cooperative, Inc.: OSHA inspections and violations

North Fort Myers, Florida · Electric Power Generation · NAICS 221119

6inspections
8citation items
$11,144current penalties
May 10, 2017last inspection

OSHA has inspected Lee County Electric Cooperative, Inc. 6 times in Florida since 2005.

The latest one began on May 10, 2017 as part of a related case, in Cape Coral.

Those inspections ended with 8 citation items: 6 serious and 2 other-than-serious.

Penalties were first proposed at $15,925 and now stand at $11,144, 30% lower after settlements or reviews.

Electric power generation, transmission, and distribution comes up most often in these citations: 4 items under 1910.269.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Lee County Electric Cooperative, Inc. averages $2,800 (1 cited inspection).

Lee County Electric Cooperative, Inc. also files yearly injury logs with OSHA, summarized below.

Lee County Electric Cooperative, Inc.: OSHA citation items per year, 2005 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

320employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Lee County Electric Cooperative, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342321536 OPENED MAY 10, 2017Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Aug 31, 2017

803 Se 10th St, Cape Coral, FL 33904 · Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341426971 OPENED APR 26, 2016Closed

Referral · Partial · Safety · 100 employees at the site · Closed Nov 2, 2016

Route 29 North, Immokalee, FL 34142 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340805506 OPENED JUL 24, 2015Closed

Complaint · Partial · Safety · 390 employees at the site · Closed Jan 13, 2016

4980 Bayline Drive, North Fort Myers, FL 33917 · Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(l)(8)(iii) · Electric power generation, transmission, and distribution
Serious$4,000$2,800Nov 13, 2015Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Nov 13, 2015Final
Citation 2, item 2
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Nov 13, 2015Final

Inspection 337890214 OPENED DEC 17, 2012Closed

Complaint · Partial · Safety · 300 employees at the site · Closed Apr 26, 2013

4980 Bayline Drive, North Fort Myers, FL 33917 · Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$4,000$2,400Apr 11, 2013Final

Inspection 313174096 OPENED APR 15, 2009Closed

Complaint · Partial · Safety · 409 employees at the site · Closed Oct 14, 2009

Wet Lands Area Known As Indian Fields Key, Pine Island, FL 33945 · Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$1,800$1,350Sep 18, 2009Closed
Citation 1, item 2
29 CFR 1910.269(a)(2)(i) · Electric power generation, transmission, and distribution
Serious$1,625$1,219Sep 18, 2009Closed
Citation 1, item 3a
29 CFR 1910.269(m)(2)(iii) · Electric power generation, transmission, and distribution
Serious$4,500$3,375Sep 18, 2009Closed
Citation 1, item 3b
29 CFR 1910.269(m)(3)(ix) · Electric power generation, transmission, and distribution
Serious$0$0Sep 18, 2009Closed

Inspection 308763812 OPENED MAR 30, 2005Closed

Planned · Partial · Safety · 500 employees at the site · Closed Mar 30, 2005

8330 Littleton Rd., North Fort Myers, FL 33903 · Electric Power Distribution · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2020, the North Fort Myers site logged 6 recordable injuries or illnesses among about 405 workers: 1.5 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 17 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Lee county Electric Cooperative
North Fort Myers · 2020
405 621.51.0

Included with any plan: 3 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

OSH Act Section 5 · General Duty Clause

Other electric power generation employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.