Inspection 341805406 OPENED SEP 27, 2016Closed
6501 Falls Of Neuse Road, Raleigh, NC 27615 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Aberdeen, North Carolina · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210
Since 1999, OSHA inspectors have visited Lee Electrical Construction, Inc. in North Carolina 11 times.
The most recent inspection opened on Sep 27, 2016, in Raleigh.
In all, OSHA issued 8 citation items: 6 serious and 2 other-than-serious.
The proposed penalties came to $22,175; today they stand at $16,500, 26% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lee Electrical Construction, Inc. averages $6,000 across 1 cited inspection.
1 inspection on this page followed a fatal incident.
Lee Electrical Construction, Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
237employers cited
2 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Lee Electrical Construction, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company6501 Falls Of Neuse Road, Raleigh, NC 27615 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Building # H-4401, Fort Bragg, NC 28307 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $5,000 | $5,000 | Feb 10, 2016 | Final |
| Citation 2, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Other-than-serious | $5,000 | $1,000 | Feb 10, 2016 | Final |
2300 Ray Road, Spring Lake, NC 28390 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12828 Us Hwy 15501, Aberdeen, NC 28315 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Nc Hwy. 410 One Mile North Of Hwy. 74, Chadbourn, NC 28431 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
May Drive & S Wesleyan Blvd, Rocky Mount, NC 27803 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Jul 7, 2010: Electric shock & burn - direct contact with overhead line
A three-person power line crew was working from aerial lifts positioned 12.2 met ers above the ground. At the time of the accident, the crewmembers were tying a center-phase overhead power line conductor to a utility pole. Two of the employe es were using tie wires to fasten the conductor to its insulator. The third empl oyee was using his aerial lift to hold the outer conductors of the 7200-volt pow er line away from the pole. One of first two employees, who was not wearing rubb er insulating sleeves, contacted the power line with his elbow, received an elec tric shock, and caused an electrical fault. He sustained second- and third-degre e burns to his upper arms and chest. The electric arc from the fault caused flas h burns to the eyes of the other employee tying in the conductor. The two injure d employees were hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.950(c)(1)(i) · Electric Power Transmission and Distribution: general |
Serious | $4,500 | $3,375 | Oct 14, 2010 | Closed |
2 Miles W Of Chadbourn On Highway 130, Chadbourn, NC 28431 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12828 Us Hwy 15/501 South, Aberdeen, NC 28315 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.253(b)(4)(i) · Gas welding and cutting |
Serious | $1,375 | $1,375 | Aug 12, 2005 | Closed |
| Citation 2, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Aug 12, 2005 | Closed |
Jinks Road And Hwy 55, Apex, NC 27539 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.955(d)(3) · Portable ladders and platforms |
Serious | $3,850 | $3,850 | Aug 12, 2005 | Closed |
Corner Of Grubb Street And East Academy Street, Hertford, NC 27930 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(15) · Fall protection in construction |
Serious | $2,450 | $1,900 | Feb 4, 2005 | Closed |
| Citation 1, item 1c 29 CFR 1926.602(c)(1)(vii) · Earthmovers and forklifts in construction |
Serious | $0 | $0 | Feb 4, 2005 | Closed |
12828 Us Hwy 15/501 South, Aberdeen, NC 28315 · OSHA's record · Phone and website on Google Maps
Incident on Feb 25, 1999 (fatal): Electric shock - direct contact with overhead line
An employee was transferring an overhead power line from an old pole to a new on e. After completing most of the work, the employee removed his leather protector s and rubber insulating gloves and donned an old pair of leather gloves. He then used a gasoline-powered chain saw to cut the top off the old pole. As he was re energizing the transformer on the new pole, he contacted the power line and was electrocuted. (He had entry and exit wounds on his left and right hands at the i ntersections of his thumbs and fore fingers.)
No citations from this inspection.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Aberdeen site logged 14 recordable injuries or illnesses among about 1,046 workers: 1.4 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 680 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Lee Electrical Construction LLC Aberdeen · 2025 | 1,046 | 14 | 13 | 1.4 | 1.8 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.215(b)(9)
(9) Exposure adjustment. Safety guards of the types described in subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b) (3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.)
29 CFR 1910.253(b)(4)(i)
(4) Oxygen storage. (i) Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.