OSHA SearchOSHA records by employer

Leech Industries, Inc.: OSHA inspections and violations

Meadville, Pennsylvania · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514

4inspections
50citation items
$17,263current penalties
Mar 12, 2019last inspection

OSHA has inspected Leech Industries, Inc. 4 times in Pennsylvania since 1994.

The latest one began on Mar 12, 2019 after a complaint, in Meadville.

Those inspections ended with 50 citation items: 37 serious and 13 other-than-serious.

Penalties were first proposed at $21,341 and now stand at $17,263, 19% lower after settlements or reviews.

Electrical equipment, general requirements comes up most often in these citations: 8 items under 1910.303.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Leech Industries, Inc. averages $6,311 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Leech Industries, Inc.: OSHA citation items per year, 1994 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Leech Industries, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343847018 OPENED MAR 12, 2019Closed

Complaint · Partial · Health · 100 employees at the site · Closed Apr 30, 2019

13144 Dickson Road, Meadville, PA 16335 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$4,508$3,156Apr 15, 2019Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$4,508$3,156Apr 15, 2019Final

Inspection 113165013 OPENED MAY 17, 1999Closed

Complaint · Partial · Safety · 195 employees at the site · Closed Oct 22, 1999

R.d. #7, State Road Hill, Meadville, PA 16335 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$975$875Sep 27, 1999Closed
Citation 1, item 2
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$975$500Sep 27, 1999Closed
Citation 1, item 3a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$975$527Sep 27, 1999Closed
Citation 1, item 3b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Sep 27, 1999Closed
Citation 1, item 3c
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Sep 27, 1999Closed
Citation 2, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Sep 27, 1999Closed
Citation 2, item 2
29 CFR 1910.25(d)(2)(viii) · Portable wood ladders
Other-than-serious$0$0Sep 27, 1999Closed
Citation 2, item 3
29 CFR 1910.37(h)(1) · Exit routes
Other-than-serious$0$0Sep 27, 1999Closed
Citation 2, item 4
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 27, 1999Closed
Citation 2, item 5
29 CFR 1910.305(g)(2)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 27, 1999Closed

Inspection 300276102 OPENED MAY 13, 1997Closed

Complaint · Partial · Safety · 150 employees at the site · Closed May 28, 1997

State Road Hill, Meadville, PA 16335 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Serious$700$525May 21, 1997Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$700$525May 21, 1997Closed
Citation 1, item 2b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 21, 1997Closed
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 21, 1997Closed
Citation 2, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0May 21, 1997Closed

Inspection 113338446 OPENED MAY 17, 1994Closed

Complaint · Partial · Health · 45 employees at the site · Closed Jan 21, 1997

State Road Hill, Meadville, PA 16335 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$625$625Jun 9, 1994Closed
Citation 1, item 2a
29 CFR 1910.24(b) · Fixed industrial stairs
Serious$500$500Jun 9, 1994Closed
Citation 1, item 2b
29 CFR 1910.25(d)(2)(i) · Portable wood ladders
Serious$0$0Jun 9, 1994Closed
Citation 1, item 3a
29 CFR 1910.36(d)(1) · Exit route design
Serious$375$375Jun 9, 1994Closed
Citation 1, item 3b
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Jun 9, 1994Closed
Citation 1, item 4a Serious$500$500Jun 9, 1994Closed
Citation 1, item 4b Serious$0$0Jun 9, 1994Closed
Citation 1, item 5 Serious$375$375Jun 9, 1994Closed
Citation 1, item 6a
29 CFR 1910.106(e)(2)(iva) · Flammable liquids
Serious$625$625Jun 9, 1994Closed
Citation 1, item 6b
29 CFR 1910.106(e)(2)(ivc) · Flammable liquids
Serious$0$0Jun 9, 1994Closed
Citation 1, item 6c
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$0$0Jun 9, 1994Closed
Citation 1, item 7a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$625$625Jun 9, 1994Closed
Citation 1, item 7b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Jun 9, 1994Closed
Citation 1, item 7c
29 CFR 1910.106(e)(9)(i) · Flammable liquids
Serious$0$0Jun 9, 1994Closed
Citation 1, item 8a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$625$625Jun 9, 1994Closed
Citation 1, item 8b
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Jun 9, 1994Closed
Citation 1, item 9
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$500$500Jun 9, 1994Closed
Citation 1, item 10
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$375$375Jun 9, 1994Closed
Citation 1, item 11a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$625$625Jun 9, 1994Closed
Citation 1, item 11b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Jun 9, 1994Closed
Citation 1, item 12
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$625$625Jun 9, 1994Closed
Citation 1, item 13a Serious$500$500Jun 9, 1994Closed
Citation 1, item 13b Serious$0$0Jun 9, 1994Closed
Citation 1, item 14
29 CFR 1910.1030(c)(1)(i) · Bloodborne pathogens
Serious$500$500Jun 9, 1994Closed
Citation 1, item 15a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$625$625Jun 9, 1994Closed
Citation 1, item 15b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Jun 9, 1994Closed
Citation 1, item 15c
29 CFR 1910.1200(h) · Hazard communication
Serious$0$0Jun 9, 1994Closed
Citation 2, item 1a Other-than-serious$0$0Jun 9, 1994Closed
Citation 2, item 1b Other-than-serious$0$0Jun 9, 1994Closed
Citation 2, item 2a
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Jun 9, 1994Closed
Citation 2, item 2b
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 9, 1994Closed
Citation 2, item 3 Other-than-serious$0$0Jun 9, 1994Closed
Citation 2, item 4
29 CFR 1910.146(c)(1) · Permit-required confined spaces
Other-than-serious$0$0Jun 9, 1994Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 3, 2023, Meadville: Hospitalization · fractures · chest, except internal location of diseases or disorders

An employee was on a ladder accessing a warehouse loft. When the employee went to step over the railing, the ladder fell and the employee fell into the safety railing. The employee sustained a sternum fracture.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(i)

(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iva)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(2)(ivc)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.20

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.332 · Training

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

29 CFR 1910.95 · Noise

Other special die and tool, die set, jig, and fixture manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.