OSHA SearchOSHA records by employer

Lee's Construction: OSHA inspections and violations

Pittsburgh, Pennsylvania · Other Building Equipment Contractors · NAICS 238290

2inspections
5citation items
$8,702current penalties
Jun 30, 2022last inspection

Since 2009, OSHA inspectors have visited Lee's Construction in Pennsylvania 2 times.

The most recent inspection opened on Jun 30, 2022 on a referral, in West Chester.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $8,702 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lee's Construction averages $8,702 across 1 cited inspection.

Lee's Construction: OSHA citation items per year, 2009 to 2022
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Lee's Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346054117 OPENED JUN 30, 2022Closed

Referral · Partial · Safety · 6 employees at the site · Closed Sep 16, 2025

250 North Bradford Avenue, West Chester, PA 19382 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$4,351$4,351Dec 28, 2022Final
Citation 1, item 1b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Dec 28, 2022Final
Citation 1, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,351$4,351Dec 28, 2022Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0Dec 28, 2022Final
Citation 1, item 2c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Dec 28, 2022Final

Inspection 312628449 OPENED JAN 13, 2009Closed

Unprogrammed other · Partial · Safety · 18 employees at the site · Closed Jan 21, 2009

North Shore Connector, Pittsburgh, PA 15212 · Other Building Equipment Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other other building equipment contractors employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.