OSHA SearchOSHA records by employer

Lemac Packaging, Inc.: OSHA inspections and violations

Erie, Pennsylvania · Printing · NAICS 323110

5inspections
23citation items
$20,335current penalties
Jan 17, 2019last inspection

Since 2001, OSHA inspectors have visited Lemac Packaging, Inc. in Pennsylvania 5 times.

The most recent inspection opened on Jan 17, 2019 on a referral, in Erie.

In all, OSHA issued 23 citation items: 15 serious and 8 other-than-serious.

The proposed penalties came to $27,168; today they stand at $20,335, 25% less.

The rule cited most here is 1910.147 (lockout/tagout), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Lemac Packaging, Inc. averages $7,823 across 2 cited inspections.

Lemac Packaging, Inc.: OSHA citation items per year, 2001 to 2019
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

299employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Lemac Packaging, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343722864 OPENED JAN 17, 2019Closed

Referral · Partial · Health · 15 employees at the site · Closed Sep 13, 2019

645 West 32nd Street, Erie, PA 16508 · Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,580$3,580Jan 23, 2019Final
Citation 1, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jan 23, 2019Final
Citation 2, item 1
29 CFR 1910.134(k)(6) · Respiratory protection
Other-than-serious$0$0Jan 23, 2019Final

Inspection 343645792 OPENED DEC 7, 2018Closed

Planned · Partial · Safety · 15 employees at the site · Closed Dec 15, 2020

645 West 32nd Street, Erie, PA 16508 · Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$5,304$3,713Jun 3, 2019Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jun 3, 2019Final
Citation 1, item 1c
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Jun 3, 2019Final
Citation 1, item 2a
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Serious$6,630$4,641Jun 3, 2019Final
Citation 1, item 2b
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$0$0Jun 3, 2019Final
Citation 1, item 2c
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Jun 3, 2019Final
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$5,304$3,713Jun 3, 2019Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jun 3, 2019Final
Citation 2, item 2
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 3, 2019Final
Citation 2, item 3
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jun 3, 2019Final

Inspection 339561318 OPENED JAN 23, 2014Closed

Follow-up · Partial · Safety · 13 employees at the site · Closed Feb 26, 2014

645 W. 32nd Street, Erie, PA 16508 · Commercial Screen Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.33(a) · Retention and updating
Other-than-serious$0$0Jan 27, 2014Final

Inspection 335522785 OPENED AUG 2, 2012Closed

Follow-up · Partial · Safety · 16 employees at the site · Closed Jan 29, 2014

645 West 32nd Street, Erie, PA 16508 · Printing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$1,600$1,600Nov 30, 2012Final
Citation 1, item 1b
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$0$0Nov 30, 2012Final
Citation 2, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Nov 30, 2012Final

Inspection 303705552 OPENED MAR 22, 2001Closed

Planned · Partial · Health · 12 employees at the site · Closed Sep 15, 2010

645 West 32nd St., Erie, PA 16508 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,750$1,100Apr 9, 2001Closed
Citation 1, item 1b Serious$0$0Apr 9, 2001Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,750$1,100Apr 9, 2001Closed
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$600Apr 9, 2001Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$500$288Apr 9, 2001Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(v) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 9, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.33 · Retention and updating

29 CFR 1904.33(a)

(a) Basic requirement. You must save the OSHA 300 Log, the privacy case list (if one exists), the annual summary, and the OSHA 301 Incident Report forms for five (5) years following the end of the calendar year that these records cover.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.332 · Training

29 CFR 1910.334 · Using electrical equipment

Other printing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.