OSHA SearchOSHA records by employer

Lester C. Groves: OSHA inspections and violations

Kenosha, Wisconsin · Other Building Finishing Contractors · NAICS 238390

1inspections
4citation items
$2,400current penalties
Jun 23, 2015last inspection

OSHA inspectors have visited Lester C. Groves in Wisconsin one time.

It opened on Jun 23, 2015, in Kenosha.

In all, OSHA issued 4 citation items: 4 serious.

The proposed penalties came to $6,400; today they stand at $2,400, 62% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Lester C. Groves averages $2,400 across 1 cited inspection.

Lester C. Groves: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

229employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Lester C. Groves and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340730969 OPENED JUN 23, 2015Closed

Unprogrammed other · Partial · Safety · 6 employees at the site · Closed Oct 28, 2015

7300 125th St., Kenosha, WI 53142 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$2,000$1,000Sep 30, 2015Final
Citation 1, item 1b
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$1,200$0Sep 30, 2015Final
Citation 1, item 2a
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$2,000$1,400Sep 30, 2015Final
Citation 1, item 2b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$1,200$0Sep 30, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.

29 CFR 1926.501 · Fall protection in construction