Inspection 349281766 OPENED NOV 12, 2026Open
113 Industrial Boulevard, Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Morganton, North Carolina · Current-Carrying Wiring Device Manufacturing · NAICS 335931
OSHA has inspected Leviton Manufacturing Co., Inc. 18 times in North Carolina since 1991.
The latest one began on Nov 12, 2026 after a complaint, in Morganton; the case is still open.
Those inspections ended with 52 citation items: 21 serious and 31 other-than-serious.
Penalties were first proposed at $59,625 and now stand at $39,420, 34% lower after settlements or reviews.
Lockout/tagout comes up most often in these citations: 8 items under 1910.147.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Leviton Manufacturing Co., Inc. averages $11,100 (2 cited inspections).
1 inspection on this page followed a fatal incident.
Leviton Manufacturing Co., Inc. also files yearly injury logs with OSHA, summarized below.
North Carolina · latest 90 days of OSHA records
228employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Leviton Manufacturing Co., Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Leviton Manufacturing Co., Inc. at 5 sites in 2 states. Together they've had 19 inspections and $45,020 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 5 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans113 Industrial Boulevard, Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $6,300 | $6,300 | Jul 8, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $7,000 | $7,000 | Jul 8, 2021 | Final |
| Citation 1, item 3 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,950 | $1,950 | Jul 8, 2021 | Final |
| Citation 1, item 4a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $1,950 | $1,950 | Jul 8, 2021 | Final |
| Citation 1, item 4b 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jul 8, 2021 | Final |
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on May 31, 2017 (fatal): Employee is struck by door, falls through opening, and is ki
At 4:29 p.m. on May 31, 2017, an employee was on the facility roof opening a fire vent door to assist roofing contractors. The employee was struck in the head by the door when it opened and the employee fell through the door opening. The employee fell approximately 22 feet before landing on the concrete surface. The employee was transported to the Carolinas Medical Center, where he was transferred to Charlotte via helicopter and was pronounced deceased. pronounced deceased.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(b)(3)(i) · Fall protection in general industry |
Serious | $5,000 | $5,000 | Jul 18, 2017 | Final |
113 Industrial Blvd., Morganton, NC 28655 · Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 26, 2013: Employee fractures thumb removing scrap from conveyor
On August 26, 2013, Employee #1, with Leviton Manufacturing Co., Inc., was remov ing a stuck part or scraps off a full revolution mechanical power press with aut omatic feeding. While removing the scraps or part, Employee #1's right thumb was crushed. Employee #1 was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Serious | $3,250 | $2,275 | Feb 21, 2014 | Closed |
| Citation 1, item 1b 29 CFR 1910.147(c)(6)(ii) · Lockout/tagout |
Serious | $0 | $0 | Feb 21, 2014 | Closed |
| Citation 2, item 1 29 CFR 1910.217(g) · Mechanical power presses |
Other-than-serious | $1,625 | $1,138 | Feb 21, 2014 | Closed |
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(b)(1)(i) · Guarding floor and wall openings and holes |
Serious | $1,650 | $1,155 | Nov 20, 2009 | Closed |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,750 | $1,925 | Nov 20, 2009 | Closed |
| Citation 1, item 3 29 CFR 1910.242(b) · Hand and power tools |
Serious | $825 | $578 | Nov 20, 2009 | Closed |
| Citation 2, item 1 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 3 29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 4 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 5 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
113 Industrial Blvd., Morganton, NC 28655 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $2,750 | $1,925 | Nov 20, 2009 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(id) · Lockout/tagout |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 4 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
| Citation 2, item 5 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Other-than-serious | $0 | $0 | Nov 20, 2009 | Closed |
8116 Nc Highway 163, W Jefferson, NC 28694 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 25, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.132(f)(1) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Apr 25, 2003 | Closed |
8116 Nc Highway 163, West Jefferson, NC 28694 · Current-Carrying Wiring Device Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(h)(1) · Belts, pulleys and power-transmission parts |
Serious | $825 | $825 | Apr 15, 2003 | Closed |
| Citation 2, item 1 29 CFR 7F0102 |
Other-than-serious | $0 | $0 | Apr 15, 2003 | Closed |
| Citation 2, item 2 29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | Apr 15, 2003 | Closed |
| Citation 2, item 3 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Apr 15, 2003 | Closed |
| Citation 2, item 4 29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting |
Other-than-serious | $0 | $0 | Apr 15, 2003 | Closed |
113 Industrial Blvd., Morganton, NC 28655 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Other-than-serious | $1,000 | $0 | Mar 12, 2002 | Closed |
113 Industrial Blvd., Morganton, NC 28655 · OSHA's record · Phone and website on Google Maps
Incident on Jun 2, 1999: Employee's hand amputated when caught in power press
At approximately 2:45 a.m. on June 2, 1999, Employee #1, a materials handler at Leviton, was helping the operator of Dorst automatic cam press #27. The press op erator had been experiencing problems with quality and she asked Employee #1, wh o was experienced on the press, to help her clear the die of excess clay. Employ ee #1 put the press in manual mode by opening the interlocked door in front of t he die, and then opened the die by jogging the controls. The 10- on press was eq uipped with two-hand controls. After the die was opened, Employee #1 held the le ft control button with his left hand while reaching in-between the dies to manua lly sweep away the excess clay. His right hand was in the press when the operato r pushed the right control button, closing the dies. He sustained crushing injur ies and was transported to St. Joseph Hospital in Asheville (NC), where his hand was surgically amputated at the wrist. Employee #1 had been employed at Leviton for two years, and had previously been a press operator.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $1,575 | $1,575 | Aug 26, 1999 | Final |
| Citation 1, item 1b 29 CFR 1910.147(c)(2)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
| Citation 1, item 2b 29 CFR 1910.217(c)(2)(ib) · Mechanical power presses |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
| Citation 1, item 2c 29 CFR 1910.217(d)(6)(i) · Mechanical power presses |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
| Citation 2, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
| Citation 2, item 2 29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
| Citation 2, item 3 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Final |
113 Industrial Blvd., Morganton, NC 28655 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts |
Serious | $975 | $630 | Aug 4, 1995 | Closed |
| Citation 2, item 1 29 CFR 1910.147(c)(4)(ii) · Lockout/tagout |
Other-than-serious | $0 | $0 | Aug 4, 1995 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(e)(1)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | Aug 4, 1995 | Closed |
1 Water Street, Old Fort, NC 28762 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $975 | $500 | Sep 1, 1994 | Closed |
| Citation 1, item 2a 29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods |
Other-than-serious | $975 | $0 | Sep 1, 1994 | Closed |
| Citation 1, item 2b 29 CFR 1910.305(a)(2)(iiig) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Sep 1, 1994 | Closed |
| Citation 1, item 3 29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods |
Serious | $975 | $975 | Sep 1, 1994 | Closed |
| Citation 1, item 4 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Serious | $975 | $500 | Sep 1, 1994 | Closed |
| Citation 2, item 1 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Sep 1, 1994 | Closed |
618 S Jefferson Avenue, West Jefferson, NC 28694 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(b)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jun 29, 1994 | Closed |
| Citation 1, item 2 29 CFR 1910.1048(m)(5) · Formaldehyde |
Other-than-serious | $0 | $0 | Jun 29, 1994 | Closed |
1 Water Street, Old Fort, NC 28762 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.36(b)(4) · Exit route design |
Serious | $14,000 | $1,610 | Nov 12, 1991 | Final |
| Citation 2, item 1a 29 CFR 1910.37(k)(2) · Exit routes |
Serious | $2,300 | $1,610 | Nov 12, 1991 | Final |
| Citation 2, item 1b 29 CFR 1910.37(q)(1) · Exit routes |
Serious | $0 | $0 | Nov 12, 1991 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Morganton site logged 12 recordable injuries or illnesses among about 501 workers: 2.4 per 100 full-time workers, against a median of 1.5 for its industry. Those cases cost 545 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Leviton Manufacturing Co., Inc. Morganton · 2025 | 501 | 12 | 6 | 2.4 | 1.5 |
| Leviton Manufacturing West Jefferson · 2025 | 77 | 4 | 2 | 5.8 | 2.6 |
| Leviton Manufacturing Company, Inc. Morganton · 2021 | 600 | 33 | 10 | 5.3 | 1.5 |
Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)(ii)
(ii) The methods the employer will use to inform employees of the hazards of non-routine tasks (for example, the cleaning of reactor vessels), and the hazards associated with chemicals contained in unlabeled pipes in their work areas.
29 CFR 1910.1200(f)(5)(i)
(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).
29 CFR 1910.132(d)(2)
(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.