OSHA SearchOSHA records by employer

Logan Corporation: OSHA inspections and violations

Louisville, Kentucky · Motor Vehicle Body Manufacturing · NAICS 336211

7inspections
43citation items
$41,790current penalties
Jan 14, 2026last inspection

OSHA has inspected Logan Corporation 7 times in Kentucky since 1986.

The latest one began on Jan 14, 2026 on a referral, in Wonnie; the case is still open.

Those inspections ended with 43 citation items: 16 serious and 27 other-than-serious.

Penalties were first proposed at $41,790 and still stand at $41,790.

Spray painting and finishing comes up most often in these citations: 6 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Logan Corporation averages $19,575 (2 cited inspections).

Logan Corporation: OSHA citation items per year, 1986 to 2026
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

181employers cited

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Logan Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348691544 OPENED JAN 14, 2026Open

Referral · Partial · Safety · 100 employees at the site · Open

124 Ward Road, Wonnie, KY 41465 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$6,300$6,300Jun 9, 2026Contested
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$6,300$6,300Jun 9, 2026Contested

Inspection 348676263 OPENED JAN 7, 2026Open

Complaint · Partial · Health · 100 employees at the site · Open

124 Ward Road, Wonnie, KY 41465 · Motor Vehicle Body Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$5,850$5,850Jun 18, 2026Contested
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$4,500$4,500Jun 18, 2026Contested
Citation 1, item 3
29 CFR 1910.38(b) · Emergency action plans
Serious$4,500$4,500Jun 18, 2026Contested
Citation 1, item 4
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$4,500$4,500Jun 18, 2026Contested
Citation 1, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$3,600$3,600Jun 18, 2026Contested
Citation 1, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$3,600$3,600Jun 18, 2026Contested
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 18, 2026Contested

Inspection 305367609 OPENED OCT 28, 2002Closed

Planned · Complete · Safety · 33 employees at the site · Closed Feb 24, 2003

200 Us Hwy 25 E, Middlesboro, KY 40965 · Paperboard Container Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.24(h) · Fixed industrial stairs
Serious$500$500Feb 3, 2003Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$625$625Feb 3, 2003Closed
Citation 1, item 3
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$375$375Feb 3, 2003Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 2
29 CFR 1910.36(b)(1) · Exit route design
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 3
29 CFR 1910.107(b)(1) · Spray painting and finishing
Serious$0$0Feb 3, 2003Closed
Citation 2, item 4
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 5
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 6
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 7
29 CFR 1910.134(e)(4) · Respiratory protection
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 8
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 9
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 10
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 11
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 12
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 13
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Feb 3, 2003Closed
Citation 2, item 14
29 CFR 2031002
Other-than-serious$0$0Feb 3, 2003Closed

Inspection 304699010 OPENED SEP 24, 2001Closed

Planned · No inspection · Safety · Closed Sep 24, 2001

200 Cabel, Louisville, KY 40206 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 112332408 OPENED JUN 7, 1990Closed

Planned · Complete · Safety · 155 employees at the site · Closed Aug 9, 1990

200 Cabel, Louisville, KY 40206 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$420$420Jul 2, 1990Closed
Citation 1, item 2
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$300$300Jul 2, 1990Closed
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Jul 2, 1990Closed
Citation 2, item 2
29 CFR 1910.107(g)(2) · Spray painting and finishing
Other-than-serious$0$0Jul 2, 1990Closed
Citation 2, item 3
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Jul 2, 1990Closed
Citation 2, item 4
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jul 2, 1990Closed

Inspection 2795946 OPENED OCT 27, 1987Closed

Follow-up · Partial · Safety · 270 employees at the site · Closed Oct 29, 1987

200 Cabel, Louisville, KY 40206 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104324454 OPENED DEC 11, 1986Closed

Planned · Complete · Safety · 270 employees at the site · Closed Jul 1, 1988

200 Cabel, Louisville, KY 40206 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$420$420Feb 24, 1987Final
Citation 1, item 1b
29 CFR 1910.217(b)(7)(v)(c) · Mechanical power presses
Serious$0$0Feb 24, 1987Closed
Citation 2, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 3
29 CFR 1910.213(b)(3) · Woodworking machinery
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 4
29 CFR 1910.217(b)(3)(i) · Mechanical power presses
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 5
29 CFR 1910.217(b)(7)(ii) · Mechanical power presses
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 7
29 CFR 1910.252(a)(5)(vib) · Welding fire safety
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 8
29 CFR 1910.252(b)(4)(ixc) · Welding fire safety
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 9
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 24, 1987Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 24, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(1)

(b) Spray booths—(1) Construction. Spray booths shall be substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.24 · Fixed industrial stairs

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1910.38 · Emergency action plans

Other motor vehicle body manufacturing employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.