OSHA SearchOSHA records by employer

Lopez House of Stone: OSHA inspections and violations

Boston, Massachusetts · Cut Stone and Stone Product Manufacturing · NAICS 327991

2inspections
3citation items
$0current penalties
Apr 19, 2018last inspection

OSHA has inspected Lopez House of Stone 2 times in Massachusetts since 2017.

The latest one began on Apr 19, 2018 to follow up on an earlier case, in Boston.

Those inspections ended with 3 citation items: 3 serious.

Penalties were first proposed at $8,148 and now stand at $0, 100% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 2 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Lopez House of Stone averages $0 (1 cited inspection).

Lopez House of Stone: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

266employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Lopez House of Stone and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343402665 OPENED APR 19, 2018Closed

Follow-up · No inspection · Health · 4 employees at the site · Closed Apr 20, 2018

314 C Street, Boston, MA 02127 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342274222 OPENED APR 25, 2017Closed

Complaint · Partial · Health · 4 employees at the site · Closed Apr 22, 2019

314 C Street, Boston, MA 02127 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,716$0Oct 23, 2017Final
Citation 1, item 2
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$2,716$0Oct 23, 2017Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,716$0Oct 23, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(d)(1)(iii)

(iii) The employer shall identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form. Where the employer cannot identify or reasonably estimate the employee exposure, the employer shall consider the atmosphere to be IDLH.

Other cut stone and stone product manufacturing employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.