Luhms Refinishing LLC: OSHA inspections and violations

Minneapolis, Minnesota · All Other Miscellaneous Wood Product Manufacturing · NAICS 321999

1inspections
4citation items
$450current penalties
Jul 10, 2019last inspection

OSHA inspectors have visited Luhms Refinishing LLC in Minnesota one time.

It opened on Jul 10, 2019 as a planned inspection, in Minneapolis.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The proposed penalties came to $750; today they stand at $450, 40% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Luhms Refinishing LLC averages $450 across 1 cited inspection.

Luhms Refinishing LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

380employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch Luhms Refinishing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344141338 OPENED JUL 10, 2019Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jan 16, 2020

936 33rd Ave Ne, Minneapolis, MN 55418 · All Other Miscellaneous Wood Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 182.653(08)
Serious$250$150Oct 4, 2019Final
Citation 1, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$375$225Oct 4, 2019Final
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$125$75Oct 4, 2019Final
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 4, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ii)

(ii) Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(b)(2)

(2) Each exit must be clearly visible and marked by a sign reading “Exit.”

Other all other miscellaneous wood product manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.